Zhao-yao SHI, Hui-ming CHENG, Yi-wen ZHU, et al. Testing machine for small-size electro-mechanical actuator used in robots[J]. Optics and precision engineering, 2020, 28(8): 1707-1714.
DOI:
Zhao-yao SHI, Hui-ming CHENG, Yi-wen ZHU, et al. Testing machine for small-size electro-mechanical actuator used in robots[J]. Optics and precision engineering, 2020, 28(8): 1707-1714. DOI: 10.3788/OPE.20202808.1707.
Testing machine for small-size electro-mechanical actuator used in robots
An electromechanical actuator (EMA) is the main component for the attitude control of robotic systems. This study focuses on solving the problems of a robot's incapability in measuring small-size EMAs
inability to reflect the machine performance comprehensively
and single measurement item. According to the characteristics of small-size EMAs
a testing machine for the comprehensive performance test was developed to measure the transmission accuracy
electric parameters
and mechanical characteristic of small-size EMAs. The testing machine mainly comprises a precision mechanical system
control hardware system
and measurement and testing software. The testing machine adopts a horizontal structure. A special fixture is designed to satisfy the measurement requirements of different types of EMAs while ensuring the accuracy of the measurement system. The developed test software not only satisfies the comprehensive measurement of multiple performance indicators of small-size EMAs
but can also analyze the measured results. Test results show that the measuring machine operated stably
with a repeatable measurement deviation of less than 3%
thereby encompassing a wide range of small-size EMAs. The precision conforms to the design requirements
and the testing machine can yield automatic precision measurements. The development of the testing machine facilitates the establishment of an overall quality evaluation system for small-size EMAs.
关键词
Keywords
references
STEWART ANDREW VACULIK. A framework for electromechanical actuator design [D]. Austin: The University of Texas at Austin, 2008.
DING H Y. Servo actuator of service robot [M]. CHINA GYEARS INDUSTRY YEARBOOK, Changchun: Jinlin Science and Technology Co.Ltd., 2018: 174-178. (in Chinese)
ZHANG F. Research on Parameters Identification and Experimental Platform of Large-scale Space Manipulator Joints [D]. Harbin: Harbin Engineering University, 2012. (in Chinese)
CH N LI , SH CAI , B ZH YANG . Experimental research on lost motion and rigidity of type 2 kV cycloidal-pin gear speed reducer . Journal of Machine Design , 2014 . 31 ( 1 ): 33 - 36 . DOI: 10.3969/j.issn.1001-3997.2014.01.010 http://doi.org/10.3969/j.issn.1001-3997.2014.01.010 .
M L TAO , Y P CHEN , D F CHEN , 等 . Research present status and outlook of harmonic reducer testing technology . Journal of Mechanical Transmission , 2018 . 42 ( 7 ): 175 - 180 . http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=jxcd201807034 http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=jxcd201807034 .
ZHAO K. Development of Performance Testing System of Harmonic Drive Reducer under Thermal Vacuum Environment [D]. Harbin: Harbin Engineering University, 2017. (in Chinese)
ZHOU L SH. Control Algorithm and Experimental Platform of Space Robot Modular Joint [D]. Beijing: Beijing University of Posts and Telecommunications, 2008. (in Chinese)
GB/T 35089-2018.机器人用精密齿轮传动装置试验方法[S].
GB-T 35089-2018. Precision transmission for robot-Test method[S]. (in Chinese)
ZH Y SHI , H XU , J C LIN , 等 . Research on measurement and evaluation system of precision reducer lost motion . Chinese Journal of Scientific Instrument , 2018 . 39 ( 6 ): 56 - 63 . http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=yqyb201806008 http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=yqyb201806008 .
ZH Y SHI , H XU , F X HAN , 等 . Current status and trends in precision reducer lost motion measurement . Opt. Precision Eng. , 2018 . 26 ( 9 ): 2150 - 2158 . http://ope.lightpublishing.cn/thesisDetails?columnId=1416741&Fpath=&index=0&l=zh http://ope.lightpublishing.cn/thesisDetails?columnId=1416741&Fpath=&index=0&l=zh .