Lin Qirong, Xie Shusen, Zhou Chuanzhao, Li Buhong, Zheng Wei, Li Hui. Laser-CCD System for Real time,Non contact and Dynamic Measurement of Diameter of Wire[J]. Editorial Office of Optics and Precision Engineering, 1997,(2): 109-115
Lin Qirong, Xie Shusen, Zhou Chuanzhao, Li Buhong, Zheng Wei, Li Hui. Laser-CCD System for Real time,Non contact and Dynamic Measurement of Diameter of Wire[J]. Editorial Office of Optics and Precision Engineering, 1997,(2): 109-115DOI:
The non diffracted laser-CCD measuring of diameter of a wire can not by now obtain practical use because of the failure of the practical method to overcome the measurement errors caused by non linear deformation of optical lens.The auto amendment method for measurement errors by microcomputer presented in this paper can solve this problem effectively.On this basis
a measurement of diameter of a wire with advantages of small volume
low cost
wide measuring range and high precision has been produced.Our system will solve the problem of real-time
non-contact and dynamic measurement of diameter of a wire especially in the real manufacturing line of enamelled wire.