浏览全部资源
扫码关注微信
1. 南开大学现代光学研究所, 光电信息技术科学教育部重点实验室 天津,300071
2. 中国科学院长春光机与物理研究所, 应用光学国家重点实验室,吉林 长春,130022
收稿日期:2001-09-10,
修回日期:2002-01-19,
网络出版日期:2002-04-15,
纸质出版日期:2002-04-15
移动端阅览
孙强, 王肇圻, 李凤友, 曹召良, 卢振武. 红外3.2~4.5μm波段折射/衍射光学系统的减热差设计[J]. 光学精密工程, 2002,(2): 121-125
SUN Qiang, WANG Zhao-qi, LI Feng-you, CAO Zhao-liang, LU Zhen-wu . Design on the athermal infrared diffractive/refractive optical system in 3.2~4.5μm[J]. Editorial Office of Optics and Precision Engineering, 2002,(2): 121-125
孙强, 王肇圻, 李凤友, 曹召良, 卢振武. 红外3.2~4.5μm波段折射/衍射光学系统的减热差设计[J]. 光学精密工程, 2002,(2): 121-125 DOI:
SUN Qiang, WANG Zhao-qi, LI Feng-you, CAO Zhao-liang, LU Zhen-wu . Design on the athermal infrared diffractive/refractive optical system in 3.2~4.5μm[J]. Editorial Office of Optics and Precision Engineering, 2002,(2): 121-125 DOI:
研究了折射/衍射光学元件的温度效应及红外系统的设计理论及具体实例
给出了在红外3.2~4.5μm波段
5°视场范围
冷光栏效率100%
在-40~80℃温度变化范围情况下的红外混合减热差系统的设计结果.结果表明
使用折射/衍射光学系统的减热差设计方案
可令相应的传统光学系统减少一片元件
并且节省了昂贵的硒化锌红外材料.不仅能在较大视场内得到接近衍射极限的成像质量
较宽的温度工作范围
而且结构简单
体积小
重量轻.
Based on the investigation on the thermal properties of the diffractive lens
the paper introduces a method and some examples for designing the athermal diffractive/refractive optical system in the infrared region. An optical system at 3.2~4.5μm with 100% cold shield efficiency
5-degree field of view was designed
associated with high optical quality at the temperature ranging from -40℃ to 80℃. With this designing scheme
there is decrease in the number of optical components for a conventional optical system by one piece
and the weight can be reduced by 1/4
and expensive Se-Zn IR material is saved. Furthermore
the image quality approaching the diffraction limit in a larger spatial field view and wider thermal range can be obtained.
常军,翁志成,姜会林,等.长焦距空间三反光学系统的设计[J].光学精密工程,2001,9(4):315-318.
李林,王煊.环境温度对光学系统影响的研究及无热系统设计的现状与展望[J].光学技术,1997,23(5):26-29.
Kanagawa Y,Wakabayashi S,Tiajime T et al.Expansion of an athermal chart into a multilens system with thick lenses spaced apart[J].Opt.Eng, 1996,35(10):3001~3006.
Jamieson T H.Thermal effects in optical systems[J].J.opt.soc.Am.1984,38:542-546.
Kanagawa Y,Wakabayashi S,Tiajime T et al.Multilens system design with an athermal chart[J].Appl.Opt, 1994,33(34):8009-8013.
Behrmann P, Bowen P.Influence of temperature on diffractive lens performance[J].Appl.Opt,1993,32(14):2483-2489.
Stone T, George N.Hybrid diffractive-refractive lenses and achromats[J].Appl.Opt,1988,27:2960-2971.
袁旭沧.光学设计[M].北京:北京理工大学出版社,1988.
0