魏彪, 冯鹏, 唐波, 潘英俊, 米德伶, 先武. X光工业用CT成像二代扫描运动控制系统设计[J]. 光学精密工程, 2003,(6): 586-590
WEI Biao, FENG Peng, TANG Bo, PAN Ying-jun, MI De-ling, XIAN Wu. Design of control system for X-ray industrial computed tomography (CT) generation-Ⅱ scanning motion[J]. Editorial Office of Optics and Precision Engineering, 2003,(6): 586-590
魏彪, 冯鹏, 唐波, 潘英俊, 米德伶, 先武. X光工业用CT成像二代扫描运动控制系统设计[J]. 光学精密工程, 2003,(6): 586-590 DOI:
WEI Biao, FENG Peng, TANG Bo, PAN Ying-jun, MI De-ling, XIAN Wu. Design of control system for X-ray industrial computed tomography (CT) generation-Ⅱ scanning motion[J]. Editorial Office of Optics and Precision Engineering, 2003,(6): 586-590 DOI:
分析X光工业用CT成像二代扫描的特点
提出了实现二代扫描的两种运动控制方案.分析并比较了二代扫描的平移和分度运动(平移+旋转)之间的关系
提出了提高系统扫描效率的两种方案.在此基础上
确定了由上位机和下位机组成的分布式运动控制系统的总体方案
设计了相应的硬件电路及软件
获得了预期的试验效果.
Two motion control schemes are proposed to realize the generation-Ⅱ scanning by analyzing the characteristics of X-ray industrial computerized tomography (CT)
and two scanning schemes are suggested to improve the scanning efficiency by analyzing and comparing the scanning motion with rotation of the generation-Ⅱ scanning method. The distributed control system consisting of upper and lower computers is then designed together with control circuits and computer software
and experimental results have been obtained as expected.
NUZZO S, PEYRIN F, MARTIN E, et al. Assessment of bone mineral content from 3-D synchrotron radiation microtomography images[J]. IEEE Trans on Nucl Sci, 2001,48(3): 859-863.
LEE S W, KIM H K, CHO G. A 3-D X-ray microtomographic system with a CMOS image sensor[J]. IEEE Trans on Nucl Sci, 2002,49(4): 1503-1505.
程耀瑜,胡欧,韩焱,等.高质量X射线数字化成像及图像采集[J].光学精密工程,2002,10(4):359-363.CHENG Y Y, HU O, HAN Y, et al. High quality X-ray digital imaging and its image collection[J]. Optics and Precision Engineering,2002,10(4):359-363.(in Chinese)
SYLVIE C, MARC D, ZLATKO D. Real-time flat-panel pixel imaging system and control for X-ray and neutron detection[J].IEEE Trans on Nucl Sci, 2002,49(2): 159-163.
先武,李时光.工业CT技术[J].无损检测,1996,18(2):156-163.XIAN W, LI SH G. Industrial computed tomography [J]. Non-destruct Test,1996,18(2):156-163.(in Chinese)
王俊普,黄胜.高精度工业CT扫描运动控制系统设计[J].机械工业自动化,1995,11(3):273-276.WANG J P, HUANG SH, High precision industrial CT scanning movement controlling system designing[J].Mechanism Industry Automatization,1995.11(3):273-276.(in Chinese)
张建平.单片机与PC机简易串行通信的实现[J].现代电子技术,1999,5(4):305-311.ZHANG J P. The realization of simple serial communications for single-chip to PC machine[J].Modern Electro-technology,1995,5(4):305-311.(in Chinese)
钟刚毅.89系列Flash单片机原理及应用[M].北京:电子工业出版社,2000.ZHONG G Y. The principle and applications of 89 series single-chip[M],Beijing:Electron Industry Publishing Company,2000.(in Chinese)
CHI H,CHEN M. Step motor driver for the let-off mechanism of looms[J]. Journal of China Textile University,English Edition,1998,15(3):537-542.
丁园杰.单片微机原理及应用[M].北京:机械工业出版社,2001.DING Y J.The principle and applications of single-chip[M].Beijing: Machinery Industry Publishing Company,2001.(in Chinese)
王晓升.改善性能的PID控制器校正方法[J].光学精密工程,2000,8(4):426-431.WANG X SH. Emendation to improving performance PID controller[J]. Optics and Precision Engineering,2000,8(4):426-431.(in Chinese)
张殿升,卢振武.面向对像分析、设计与编程[J].光学精密工程,2000,8(6):643-647.ZHANG D SH,LU ZH W. Facing to object analysis,designing and programme[J], Optics and Precision Engineering,2000,8(6):643-647. (in Chinese)
0
浏览量
265
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621