
浏览全部资源
扫码关注微信
西北核技术研究所 西安,710024
收稿日期:2003-05-27,
修回日期:2003-08-01,
网络出版日期:2003-10-15,
纸质出版日期:2003-10-15
移动端阅览
李红艳, 俞士胜, 任向军, 邓虎. 激光共振电离质谱计用光入射系统的研制[J]. 光学精密工程, 2003,(5): 461-465
LI Hong-yan, YU Shi-sheng, REN Xiang-jun, DENG Hu. Development of light incidence system for laser resonance ionization mass spectroscopy[J]. Editorial Office of Optics and Precision Engineering, 2003,(5): 461-465
针对NINT3000质谱计的结构特点
利用高斯光学理论
推导出双透镜系统光学参数传递方程
并以此为依据设计出一套光学系统和光路调整装置
实现了激光束在离子源腔内的精确定位和聚集
焦斑半径为160μm
调节精度为10μm。目前
该系统已经安装在激光共振电离质谱计上
并实现了镥的单色双光子共振电离。
An equation has been established for the transmission of optical parameters in a two-lens system using the Gaussian optical theory
and in the light of the structural features of NINT3000 laser resonance ionization mass spectrometer
an optical system and a laser path adjustment device were then designed using the above equation to achieve precise location and focusing of laser beam in the ion source cavity. The radius of the laser focal spot is 160 μm
and the adjusting precision being 10 μm. The system has now been installed in the laser resonance ionization mass spectrometer
and the homochromatic two-photon resonance ionizations of lutetium has been realized.
朱凤蓉.激光共振电离质谱学及应用[J].国外核试验技术,1990,13(3):1-18.ZHU F R. Laser resonance ionization mass spectroscopy and the application[J]. Nuclear and High Technology Development Abroad, 1990,3(3):1-18.
李春明,戴松涛.溅射原子化激光共振电离-飞行时间质谱仪的研究及应用进展[J].光谱学与光谱分析,1997, 17(1): 102-107.LI CH M, DAI SH T. Development of a SIRI-TOFMS and the application research progress[J]. Spectroscopy and Spectral Analysis, 1997, 17(1): 102-107.
史桂珍.铀原子多色三光子共振电离谱研究[J].光谱学与光谱分析,2000, 20(1):5-8.SHI G ZH. The multicolor three-photon resonant ionization spectrum studies in uranium atom[J]. Spectroscopy and Spectral Analysis, 2000, 20(1): 5-8.
MILLER C M. Resonance ionization spectroscopy[J]. J Opt Soc Am B,1985, 12(6): 897-902.
RUSTER W.Detection of very rare isotopes by collinear resonance ionization of accelerated atoms[A]. Inst Phys Conf Ser[C].1989. 114-119.
常军,翁志成,姜会林,等.宽覆盖、离轴空间相机光学系统的设计[J].光学精密工程,2003,11(1):55-57.CHANG J, WENG ZH CH, JIANG H L,et al. Design of optical system for space camera with long focal length, wide coverage and high resolution[J]. Optics and Precision Engineering, 2003,11(1):55-57.
杜俊峰.楔铁式调平机构的设计[J]. 光学精密工程,2003,11(3):301-304.DU J F. Design of the wedge lever[J]. Optics and Precision Engineering, 2003,11(3):301-304.
杨劲松.光学镜头机械结构参数化设计系统的开发[J]. 光学精密工程,1999,7(6):6-9.YANG J S. A parameter design system for mechanical structure[J]. Optics and Precision Engineering, 1999,7(6):6-9.
吴晗平.激光束光束质量的评价与应用分析[J].光学精密工程,2000,8(2):128-132.WU H P. Evaluation and applied analysis of laser beam quality[J]. Optics and Precision Engineering, 2000,8(2):128-132.
李志明,余士胜,张子斌,等.利用激光质谱从镱镥混合物中测定镥同位素比值[J].质谱学报,1999,20(3,4):34-35.LI ZH M, YU SH SH, ZHANG Z B,et al. Measurement of lutetium isotope ratio in the mixture of ytterbium and lutetium by laser resonance ionization mass spectrometer[J]. Journal of Chinese Mass Spectrometry Society Transaction, 1999,20(3,4):34-35.
0
浏览量
359
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621