浏览全部资源
扫码关注微信
南京航空航天大学, 机电学院,江苏 南京,210016
收稿日期:2003-11-21,
修回日期:2003-12-14,
网络出版日期:2004-02-15,
纸质出版日期:2004-02-15
移动端阅览
叶寒, 廖文和, 沈建新. 波前像差引导的角膜切削模型及实现技术的研究[J]. 光学精密工程, 2004,(1): 31-36
YE Han, LIAO Wen-he, SHEN Jian-xin. Wavefront guided ablation on cornea[J]. Editorial Office of Optics and Precision Engineering, 2004,(1): 31-36
对波前像差概念和表示方法做了必要的叙述
深入研究了波前像差引导的角膜个性化切削模型
推出了角膜手术区域中角膜修正量的基本公式
给出了实现个性化像差矫正手术的软硬件框图.采用该模型引导的扫描频率为120Hz
光斑直径为0.9mm的准分子激光眼科治疗机做PMMA试验
对比传统的屈光不正矫正模型
在手术区域直径为6.5mm条件下
给出了近视、远视、近视散光各种情况下手术的最大切削深度和切削时间.试验结果表明
各种情况下角膜最大切削深度基本相同
波前像差矫正切削模型的切削时间稍大
PMMA板切削效果良好.
The customized ablation based on the individual eye's wavefront aberrations and the ablation depth in corneal zone were studied and the hardware and software used for wavefront aberrations were developed for refractive surgery. According to this model
a scanning-spot laser with a 1.0 mm spot size and a 200 Hz repetition rate were used. Under the condition that the treatment area diameter is 6.5 mm
the PMMA result to myopia
hyperopia
astigmatism is that the maximal depth is equal and the time needed is a little bigger than the refractive errors of guided Lasik model
the result shows that the wavefront guided Lasik model is acceptable.
周翔天,瞿佳. 波前理论在视觉质量方面的应用及其意义[J].眼视光学杂志,2000,2(3):182-185.ZHOU X T, QU J. The principle of the wavefront using in visual performance[J]. China J Optomophthalmol,2000,2(3):182-185.(in Chinese)
张运海,沈建新,廖文和.准分子激光矫正复性近视散光的屈光学机理和应用[J].光学精密工程,2003,11(3):293-295.ZHANG Y H, SHEN J X, LIAO W H.Use of excimer to correct compound myopic astigmatism[J].Optics and Precision Engineering,2003,11(3):293-295.(in Chinese)
刘后仓.波前像差技术与屈光手术[J].中国实用眼科杂志,2002,20(7):484-485.LIU H C. Wavefront aberration and ocular surgery[J]. Chinese Journal of Practical Ophthalmology,2002:484-485.(in Chinese)
刘风,综述,唐罗生.波前像差及波前像差仪在眼科中的应用及发展[J].中国实用眼科杂志,2001,19(12):883-886.LIU F, ZONG S, TANG L SH. The using and development in the ocular surgery with wavefront and wavefront sensor[J]. Chinese Journal of Practical Ophthalmology,2001,19(12):883-886.(in Chinese)
金红颖,王勤美. 波阵面像差技术在临床上的应用[J].眼视光学杂志,2002,4(1):57-58.JIN H Y, WANG Q M. Use of wavefront aberration techniques in clinical procedures[J]. Chinese Journal of Optometry & Opthalmology,2002,4(1):57-58.(in Chinese)
CHARMAN W N. Wavefront aberration of the eye: a review[J]. Optom Vis Sci,1991, 68(8):574-583.
THIBOS L N,APPLEGATE R A,SCHWIEGERLING J T,et al. Standards for reporting the optical aberrations of eyes[Z]. jrs.slackinc.com/vol185/thi.pdf
Larry N, Thibos O D. Wavefront-guided contact lens design principles[J].Techniques and Limitations, 2003(1):35-37.
叶寒, 沈建新, 廖文和.准分子激光屈光矫正系统设计与实现[J].应用激光,2003,23(3):164-166.YE H, SHEN J X, LIAO W H. Design and implementation of the ophthalmic excimer laser system[J].Applied Laser,2003,23(3):164-166.(in Chinese)
沈建新,胡利刚,廖文和.准分子激光角膜的数学模型与切削技术研究[J].激光生物学报,2003,12(1):1-6.SHEN J X, HU L G, LIAO W H.The corneal model and ablation in excimer laser sugery system[J].Laser Biology,2003,12(1):1-6.(in Chinese)
贺极苍.波前像差及其在眼科学和视光学中的应用[C].第五届青岛国际眼科学术研讨会.HE J CH.Wavefront aberration & its applications in ophthalmology and optometry[C].Qingdao:The Fifth International Conference on Ophthalmology.(in Chinese)
0
浏览量
436
下载量
4
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621