利用椭圆从一个焦点发射出的光线经椭圆面反射必汇聚于另一焦点的性质
设计了基于620~6200eV的X射线椭圆弯晶谱仪.文中分析了系统原理
完成了谱仪光学色散系统、探测系统及仪器的研制.采用KAP、LiF、PET、MiCa作为色散元件
其2d值在0.4~2.6nm、Bragg角为30°~67.5°
晶体尺寸为120×8×0.2mm
偏心率为0.9586
焦距1350mm
光程长1456mm
分析器基底材料用数控铣床加工.实验在上海"神光Ⅱ"号装置上实施
激光能量为150J
波长为0.35mm
真空度为3×10
-3
Pa.为达到光学对准
采用了小点光源以及精密望远镜对中.实验结果显示出金靶在0.63~0.79nm范围
其分辨力(△λ/λ)达到了1/486.谱的分辨力还与晶体特征和激光靶源尺寸有关.谱仪性能良好、使用方便、简单
具有高的收集效率和分辨能力
能够有效获取激光惯性约束聚变中激光等离子体发射光谱的丰富信息.
Based on the theory that is ray emitted from a focus(front)of an ellipse will converge on the other focus(back)by the reflection on the elliptical surface
the Elliptical Crystal Spectrograph(ECS)in the X-ray region of 620~6200 eV was designed. The principle of the system was analyzed
and the design and manufacture were accomplished. KAP
LiF
PET and MiCa are used as dispersive elements covering Bragg angle from 30°to 67.5°. The crystal sizes are 120×8×0.2 mm with the curved analyzer substrate of eccentricity ε=0.9586
focal distance of 1350 mm
and optical path length of 1456 mm. The analyzer of the elliptical profiles was machined into a suitable substrate material using a Computer-Controlled milling machine. The Elliptical Crystal Spectrograph was experimented on Shanghai "Shenzhou Ⅱ" with laser energy of 150 J
laser wavelength of 0.35 μm
and chamber vacuum level 3×13
-3
Pa. To achieve optical alignment with a small point source
an aligned telescope was precisely fitted to the elliptical analyzer block. The result shows that spectra of Au target can be measured in 0.63~0.709 nm with a resolution of 1/486(△λ/λ). It is found that the resolution of the spectrograph depends on the rocking curve and the thickness of the crystal and the laser spot diameter. In addition
ECS is simpler and easier to use
with a higher collecting efficiency and a better resolution. It can effectively obtain abundant information of the laser-plasma emission spectra in an inertial confinement fusion.
HAUER A A,DELAMATER N D,KOENIG Z M.High-resolution X-ray spectroscopic diagnostics of laser-heated and ICF plasmas[J]. Laser Part. Beams.,1991,9(1):3-5.
AGLITSKIY Y,LEHECKA T,OBENSCHAIN S,et al. X-ray crystal imagers for inertial confinement fusion experiments(invited)[J]. Rev. Sci. Instrum., 1999,70(1):530-532.
ARORA V,KUMBHARE S R,NAIK P A,et al. A simple high-resolution on-line X-ray imaging crystal spectrograph for laser-plasma interaction studies[J].Rev. Sci. Instrum., 2000, 71(7): 2644-2648.
CAMPBELL E M.Recent results from the Nova program at LLNL[J]. Laser Part. Beams., 1991, 9(2):209-212.
NAGATA Y,MIDORIKAWA K,KUBODERA S.Soft-X-ray amplification of the Lyman- alpha transition by optical-field-induced ionization[J]. Phys. Rev. Lett., 1993, 71(23):3774-3776.
FIEDOROWICZ H,BARTNIK A,LI Y,et al.Demonstration of Soft X-ray lasing with neonlike argon and nickel-like xenon ions using a laser-irradiated gas puff target[J]. Phys. Rev. Lett., 1996, 76(3):415-417.
HUILLIER A L,BALCOU P. High-order harmonic generation in rare gases with a 1 ps 1 053 nm laser[J]. Phys. Rev. Lett., 1993,70(6):774-778.
TURCU I C E,DANCE J B.X-rays from Laser Plasmas[M]. Wiley, New York, 1999.
CHAKER M,LA FONTAINE B,COTE C Y,et al.Laser plasma sources for proximity printing or projection X-ray lithography[J]. Sci. Technol.,1992, B 10:3239-3241.
STEAD A D,COTTON R A,DUCKETT J G,et al.Use of soft x rays to study the ultrastructure of living biological material[J]. X-Ray Sci. Technol., 1995, 5(1):52-54.
HAMMEL B A,KEANE C J,KANIA D R,et al.K- and L-shell X-ray spectroscopy of indirectly driven implosions(invited)[J]. Rev. Sci. Instrum., 1992, 63(10):5017-5019.
孙景文.高温等离子体X射线谱学[M].北京:国防工业出版社,2003.SHUN J W.High-temperature plasma X-ray spectroscopy[M].Beijing: National Defence Industry Press,2003.(in Chinese)
项志遴,俞昌旋.高温等离子体诊断技术[M].上海:上海科学技术出版社,1982.XIANG ZH L,YU CH X.High-temperature plasma diagnostic technology[M].Shanghai:Shanghai Scientific and Technical Publishers,1982.(in Chinese)
王峰,徐朝银,潘国强,等. 同步辐X射线双晶体单色仪能量扫描[J].光学精密工程,2001,9(4): 401-404.WANG F,XU CH Y,PAN G Q,et al.Energy scanning of the double crystal monochromator at X-ray beam Lines[J].Optics and Precision Encineering,2001,9(4): 401-404.(in Chinese)
熊先才,钟先信,肖沙里,等.双通道椭圆弯晶谱仪的传递效率分析[J].光学精密工程,2002,10(6):592-596.XIONG X C,ZHONG X X,XIAO SH L,et al.Analysis of the transmission efficiency of a two-channel elliptical crystal spectrometer[J]. Optics and Precision Engineering, 2002, 10(6):592-596.(in Chinese)
王英华. X光衍射技术基础[M].北京:原子能出版社,1993:81-83.WANG Y H.Fundament of X-ray diffraction technology[M].Beijing:Atomic Energy Press, 1993:81-83.(in Chinese)
杨福家. 原子物理学[M].北京:高等教育出版社,2000:250-256.YANG F J. Atomic physics[M].Beijing:Higher Education Press,2000:250-256.(in Chinese)
0
浏览量
583
下载量
2
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621