浏览全部资源
扫码关注微信
1. 中国科学院 研究生院 北京,100039
2. 中国科学院, 长春光学精密机械与物理研究所, 应用光学国家重点实验室, 吉林, 长春, 130033
收稿日期:2004-04-22,
修回日期:2004-07-18,
网络出版日期:2004-08-15,
纸质出版日期:2004-08-15
移动端阅览
邢进, 王淑荣, 李福田. 紫外-真空紫外辐射标准光源的比对[J]. 光学精密工程, 2004,(4): 373-379
XING Jin, WANG Shu-rong, LI Fu-tian. Comparisons between radiometric scales on UV-VUV radiant standard light sources[J]. Editorial Office of Optics and Precision Engineering, 2004,(4): 373-379
建立了高精度光谱辐射计量系统
给出了164~300nm波长间3个光谱辐射标准氘灯光源的比对结果.其中3个光谱辐射标准氘灯光源分别以德国国家物理技术研究院(PTB)BESSYⅡ同步辐射、英国国家物理实验室(NPL)Daresburg同步辐射、中国合肥(国家同步辐射实验室)同步辐射为标准标定.实验中采用相互交替的比对顺序、微机控制比对时间以及抛光氘灯端窗等方法有效的消除了系统误差.实验数据分析结果表明:3个光谱辐射标准氘灯光源的相对光谱分布
在各自给定的不确定度范围内相一致
这也间接的验证了各国建立的紫外 真空紫外辐射标准的一致性.实验中比对引进的误差为1.7%.同时也研究了氘灯的光谱辐射特性.
A high precision spectroradiometric system was established
and the comparisons between three spectral radiant standard sources-deuterium lamps in the range of 164~300nm were given. The three transfer standard deuterium lamps are calibrated based on: BESSYⅡ Synchrotron Radiation of German National Institute of Science and Technology for Metrology(PTB)
Daresburg Synchrotron Radiation of National Physical Laboratory(NPL)in UK
and Synchrotron radiation of HeFei National Laboratory of Synchrotron Radiation in China
respectively as primary standard sources. A series of methods
such as alternative sequence of comparison
computer controlled time consuming
and polishing the window of the deuterium lamp
was adopted to eliminate the systemic error efficiently. And the experimental result data were analyzed. It shows that the relative spectral radiant distributions of the lamps are consistent within the uncertainties designated respectively. It also shows that the consistency between UV-VUV radiometric standards established by different countries is confirmed. The error arising from the comparison is estimated at 1.7%. Meanwhile the spectral radiation characteristics of deuterium lamps are demonstrated.
KEY P J,WARD T H.The Establishment of ultraviolet spectral emission scales using synchrotron radiation[J].Metrologia,1978,14(1):17-29.
KEY P J,PRESTON R C.Vacuum ultraviolet radiation scales: an accurate comparison between plasma blackbody lines and synchrotron Rradiation[J].Appl. Opt.,1977,16(9):2477-2485.
KEY P J,PRESTON R C.Magnesium fluoride windowed deuterium lamps as radiance transfer standards between 115 nm and 370 nm[J].J. Phys. E. Sci. Instrum.,1986,13:866-870.
SAUNDERS R D,OTT W R.Spectral irradiance standard for the ultraviolet: the deuterium lamp[J].Appl. Opt.,1977,17(4):593-600.
KEY P J,LI F T,NETTLETON D H.NPL Report Qu 65 April.1983[Z].
FURST M L,GRAVES R M,MADDEN R P.Synchrotron ultraviolet radiation facility(SURFⅡ)radiometric instrumentation calibration facility[J].Optical Engineering,1993,32(11):2930-2935.
LEMKE D,LABS D.The Synchrotron radiation of the 6-GeV DESY machine as a fundamental radiometric standard[J].Appl. Opt.,1967,6(6):1043-1048.
PITZ E.Absolute calibration of light sources in the vacuum ultraviolet by means of the synchrotron radiation of DESY[J].Appl. Opt.,1969,8(2):255-259.
FISCHER J,KUHNE M,WENDE B.Spectral radiant power measurements of VUV and soft X-ray sources using the electron storage ring BESSY as a radiometric standard source[J].Appl. Opt.,1984,23(23):4252-4259.
STOCK M,FISCHER J,FRIEDRICH R,et al.Present state of the comparison between radiometric scales based on three primary standards[J].Metrologia,1993,30:439-449.
唐玉国.同步辐射、壁稳氩弧紫外-真空紫外光谱辐射标准的研究[D].中国科学院长春光学精密机械与物理研究所,1995.TANG Y G.Studies of spectral radiometric standards established using synchrotron radiation and wall-stabilized argon arc source in UV and VUV[D].Changchun Institute of Optics and fine Mechanics Chinese Academy of science,1995.(in Chinese)
刘颖,李福田.两种紫外-真空紫外光谱辐射标准的比对[J].光谱学与光谱分析,2000,21(4):427-431.LIU Y,LI F T.The comparison between radiometric scales on two UV and VUV spectral emitting standards[J].Spectroscopy and Spectral Analysis,2000,21(4):427-431.(in Chinese)
ARNOLD D,ULM G.Electron storage ring BESSY as a source of calculable spectral photon flux in the X-ray region[J].Rev. Sci. Instrum.,1992,63(1): 1539-1542.
0
浏览量
852
下载量
7
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621