浏览全部资源
扫码关注微信
天津大学, 电子信息工程学院, 天津, 300072
收稿日期:2004-07-19,
修回日期:2004-08-16,
网络出版日期:2004-10-15,
纸质出版日期:2004-10-15
移动端阅览
王林斗, 王加新, 邢文烈, 李玉峰. 具有隔离器功能的激光干涉仪的研究[J]. 光学精密工程, 2004,(5): 465-470
WANG Lin-dou, WANG Jia-xin, XING Wen-lie, LI Yu-feng. Laser interferometer with isolator function[J]. Editorial Office of Optics and Precision Engineering, 2004,(5): 465-470
提出了一种具有隔离器功能的激光干涉仪.既可以进行干涉测量
又具有隔离器功能
可以防止反射光回到光源
使光源保持稳定
确保了测量精度.该干涉仪由常规干涉仪和双级隔离器的结构有机的结合起来
其中某些元件合二为一
使一个元件起到双重功能的作用
同时使干涉光路和隔离光路也相互重合起来.理论分析和实验研究表明:该方案是可行的.隔离度与双级隔离器的隔离度相同
达到了48dB.该装置的干涉测量精度与一般干涉仪一样取决于激光波长
但该装置结构紧凑
简化了测量系统
实际使用更为方便.
A laser interferometer with isolator function is proposed. It can be used to carry out interference measurement
and at the same time can be prevent reflected light from returning into the laser source to stabilize the source as an isolator does
thus the measurement accuracy can be guaranteed. So
the structure of the device is formed by organic combing two structures of the conventional interferometer and two-stage isolator
in which some elements can be combined two into one with double function. And the optical paths of the interference measurement and isolating are overlapped. Theoretic analysis and experiment results show that the device is effective
the isolation is agrees with that of a two-stage isolator
about 48 dB up to now. The results also show that the accuracy of the interference measurement depends on the wavelength of the laser like that of the general interferometer. But with compact structure
it simplifies the measurement system and is convenient for practical uses.
SUN C K, YE S H.Laser measurement techniques [M] . Tianjin: Tianjin Univ. press, 2001.(in Chinese)
DING J H, CUI Y S, WU M J.Laser principle and application [M] . Beijing: Tsing-Hua Univ. press, 1987.(in Chinese)
SONG K,ZHAO Y L,JIANG Z D.Laser profilometer[J] . Optics and Precision Engineering,2003,11(3):245-249.(in Chinese)
LI C,ZHANG Y M,TIAN X F,WU S.Optical design for wedg-adjusted Talbot interferometer[J] . Optics and Precision Engineering, 2003,11(5):453-456.(in Chinese)
HONG H T,YE S H.Research on the positioning method for interferometer system of absolute distance measurement[J] . Optics and Precision Engineering, 1999,7(1):110-115.(in Chinese)
GREEN A E,GEORGIOU G. Compact bulk optical isolator with monomode fibre pigtails for use at 1.3 μm[J] .Electronics Letters, 1986,22(20):1045-1046.
MATSUMOTO S, SUZUKI S. Temperature-stable Faraday rotator material and its use in high-performance optical isolators[J] .Appl. Opt., 1986, 25(12):1940-1945.
YOKOI H,MIZUMOTO T,SHINJO N, et al. Feasibility of integrated optical isolator with semiconductor guiding layer fabricated by wafer direct bonding[J] . IEEE Proc-Optoecectron, 1999,146(2):105-109.
BAHLMANN N,LOHMEYER M,D otsch, et al.Integrated magneto-optic Mach-Zehnder interferometer isolator for TE modes[J] . Electronics Letters,1998,34(22):2122-2123.
KOGA M, MATSUMOTO T. High-isolation polarization-insensitive optical circulator for advanced optical communication systems[J] .J. Lightwave Technol., 1992, 10(9): 1210-1217.
CHANG K W, SORIN W V. High-performance single-mode fiber polarization-independent isolators[J] .Opt. Lett.,1999,15(8): 449-451.
WANG L D, ZHU S X, LI Y F, et al. Accurate Jones matrix of the practical Faraday rotator[J] .Trans. of Tianjin Univ., 2003, 9(3):198-201.
0
浏览量
566
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621