浏览全部资源
扫码关注微信
1. 吉林化工学院 机电系,吉林 吉林,132022
2. 吉林大学 机械科学与工程学院, 吉林 长春 130022
收稿日期:2005-03-12,
修回日期:2005-04-14,
网络出版日期:2005-06-30,
纸质出版日期:2005-06-30
移动端阅览
曾 平, 程光明, 刘九龙, 等. 双腔薄膜阀压电泵的实验研究[J]. 光学精密工程, 2005,13(3):311-317.
ZENG Ping, CHENG Guang-ming, LIU Jiu-long, et al. Experimental research on double-chambered piezoelectric pump with membrane valves[J]. Optics and precision engineering, 2005, 13(3): 311-317.
实验研究了理论所不能解释的多种因素对双腔压电泵输出流量的影响规律。选取了一种高效的橡胶薄膜阀片
设计并制作了具有较高输出能力的双腔泵样机。120 V交流信号下
双腔串联压电泵最佳工作频率为180 Hz
输出参数为520 ml/min、22 kPa;双腔并联压电泵最佳工作频率为420 Hz
输出参数为980 ml/min、28 kPa。通过实验确定了双腔压电泵的最佳腔体高度及双腔串联、并联压电泵压电片的最佳驱动方式。
By experiment
many factors affecting the output ability of piezoelectric (PZT) pumps with double chambers are studied
which can't be explained with theories. A high efficient rubber membrane valve was made
and double-chambered PZT pump with high output capability was designed and fabricated. When powered by AC 120 V
series-wound PZT pump has a output of 520 ml/min
22 kPa
and parallel-connectioned PZT pump has a output of 980 ml/min、28 kPa. The optimal chamber height is found
and PZT diaphragm actuating ways in series-wound and parallel-connectioned pumps are proved.
. SPENCER W J,CORBETT W T,DOMINGUEZ L R,et al.An electronically controlled piezoelectric insulin pump and valves[J].IEEE Trans.Sonics Ultrasonics,1978,SU-25(3):153-156.
. van LINTEL H T G, VAN DE POL F C M, BOUWSTRA S. A piezoelectric micropump based on micromachining of silicon [J]. Sensors and Actuators, 1988,15:153-167.
. LINNEMANN R,WOIAS P, SENFF C D, et al. A self-priming and bubble-tolerant piezoelectric silicon micropump for liquids and gases . Proc. 12th IEEE MEMS 1998 Technical Digest,Heidelberg, Germany,1998:532-537.
. MAILEFER D, van LINTEL H, MERMET G R, et al. A high-performance silicon micropump for an implantable drug delivery system . Proc. of the 12th IEEE MEMS 1998 Technical Digest, Orlando, Florida, USA,1/17-21/1999:541-546.
. SHOJI S, NAKAGAWA S, ESASHI N. Micropump and sample-injector for integrated chemical analysis system [J]. Sensors and Actuators A, 1990, 21-23:189-19.
. EDERER I, RAETSCH P, SCHULLERUS W, et al. Piezoelectrically driven micropump for on-demand duel-drop generation in an automobile heater with continuously adjustable power output [J]. Sensors and Actuators A, 1997,62:752-755.
. LI H Q, RIBERTS D C, STEYN J L, et al. A high frequency high flow rate piezoelectrically driven MEMS micropump . Proceeding IEEE Solid State Sensors and Actuators Workshop Hilton Head, 2000.
. MICHAEL K, NICK H, EVANS AL G R. A novel micromachined pump based on thick-film piezoelectric actuation [J]. Sensors and Actuators A, 1998,70: 98-103
. NGUYEN N T, WHITE R M. Design and optimization of an ultrasonic flexural plate wave micropump using simulation [J]. Sensors and Actuators, 1999,77:229-236.
. COHEN Y B, CHANG Z. Piezoelectrically actuated miniature peristaltic pump [J]. SPIE, 2002,3992:669-676.
. MENG A H, NGUYEN N T, WHITE R M. Focused flow micropump using ultrasonic flexural plate waves [J]. Biomedical Microdevices, 2000,2(3): 169-174.
. COHEN Y B, CHANG Z. Piezoelectrically actuated miniature peristaltic pump [J]. SPIE, 2001,4327:425-432.
. KOJIMA Y, OKUSAWA T,TSUBOUCHI K, et al. Fundamental investigation of a piezoelectric pump for a trace liquid feed [J]. JMSE International Journal, Series C, 1995, 38(3): 531-537.
. STEMME E, STEMME G. A valveless diffuser/nozzle-based fluid pump [J]. Sensors and Actuators A, 1993,39:159-167.
. ULMANN A. The piezoelectric valveless pump-performance enhancement analysis [J]. Sensors and Actuators A, 1998,69:97-105.
. GERLACH T, SCHUENEMANN M,WURMUS H. A new micropump principle of the reciprocating type using pyramidic micro flowchannels as passive valves [J]. J.Micromech. Microeng., 1995,5:199-201.
. GERLACH T, WURMUS H,Working principle and performance of the dynamic micropump [J]. Sensors and Actuators A, 1995,50:135-140.
. 程光明,杨志刚,曾平,等. 压电薄膜流体泵的初步研究 . 压电与声光.1998,20(4):233-236. CHENG G M, YANG ZH G, ZENG P, et al. Primary research on piezoelectric membrane fluid pump [J]. Piezoelectrics and Acoustooptics,1998,20(4):233-236.(in Chinese)
. MATSUMOTO S, KLEIN A, MAEDA R. Development of bi-directional valve-less micropump for liquid . Proc. IEEE MEMS, 1999:141-146.
. OLSON A, STEMME G,STEMME E. A valveless planar fluid pump with two pumps chambers [J]. Sensors and Actuators A, 1995,46-47:549-556.
. OLSON A, STEMME G, STEMME E. A numerical design study of the valveless diffuser pump using a lumper-mass model [J]. J. Micromech. Microeng., 1999,9:34-44.
. 张建辉,夏齐霄,王大康等. 抽样定理在周期性非连续信号的压电泵气穴现象中的应用方法[J]. 光学 精密工程,2002,10(5):476-482. ZHANG J H,XIA Q X,WANG D K, et al. Sample theorem to periodic non-continuous signal from cavitation of piezoelectric pump [J]. Optics and Precision Engineering, 2002,10(5): 476-482.(in Chinese)
. 阚君武,杨志刚,程光明. 压电泵的现状与发展[J]. 光学 精密工程.2002,10(6):619-625. KAN J W,YANG ZH G,CHENG G M. Actuality and development of piezoelectric pump [J]. Optics and Precision Engineering, 2002,10(6): 619-625.(in Chinese)