移动端阅览
马军山, 侯琳琳, 付东翔, 等. 双荧光标记生物芯片激光共聚焦检测系统[J]. 光学精密工程, 2005,13(6):727-734.
MA Jun-shan, HOU Lin-lin, FU Dong-xiang, et al. Two-laser scanning confocal system for microarray analysis[J]. Optics and precision engineering, 2005, 13(6): 727-734.
基于激光共聚焦检测原理
构建了针对荧光标记生物芯片的检测系统
对用Cy
3
或Cy
5
标记蛋白点样的玻片进行了扫描检测
并对采集的荧光数据信号进行了图像重建。针对实际荧光信号可能较微弱并存在较大动态范围的情况
采用形态学方法对图像进行滤波、增强处理
显著增强了图像质量。提出了标定系统信噪比和灵敏度的公式
并据此对检测实验结果进行了详细的分析计算
最终标定此激光共聚焦生物芯片检测系统的灵敏度约为0.1 fluo/μm
2
。
A dual-fluorescence microarray scanner based on laser confocal principle was constructed to detect the Cy
3
-protein or Cy
5
-protein dotted slides. The images were constructed according to the fluorescent intensity signals
and enhanced through adopting the technique of morphologic methods to meet the situation in which the fluorescent intensity was very low and the dynamic range of the data was wide relatively. The measuring ways of the signal-to-noise ratio and the sensitivity of the system were put forward
and the measurement result shows the sensitivity of the system is about 0.1 fluo/μm
2
.
. SOUTHERN E M. Analyzing polynucleotide sequences , International Patent Application: PCT GB 89/00460,1998.
. 马立人,蒋中华.生物芯片[M].北京:化学工业出版社,2002.170-176 MA L R,JIANG ZH H.Biochiop[M].Beijing:Chemical Industry Press,2002.170-176.(in Chinese)
. GU M. Principles of three-dimensional imaging in confocal microscopes[M]. Singapore: World Scientific Publishing Co.Ltd., 1996. 288-290.
. GRAVES D J,SU H J, ADDYA S, et al. Four-laser scanning confocal system for microarray analysis[J]. BioTechniques, 2002, 2(32): 346-354.
. TIANCHUN Z, CE W,JIANHONG W, et al. A laser confocal scanning system with holographic filters used for genechip detection [J]. Laser Journal, 2003, 6(24):42-44.(in Chinese)
. DRMANAC R, LABAT I, RUKET I, et al. Seqencing of megabase plus DNA by hybridization[J]. Theory of the Method Genomics, 1989,4:114-128.
. 唐常青,吕宏伯,黄铮,等.数学图形学方法及其应用[M]. 北京:科学技术出版社,1990:94-100. TANG CH Q, LU H B, HUANG ZH, et al. Mathematical morphologic and the application[M]. Beijing: Scientific & Technical Publishers, 1990:94-100.(in Chinese)
. 吴敏金. 图像形态学[M]. 上海:上海科学技术文献出版社,1991,160-183. WU M J. Morphologic image processing[M]. Shanghai: Shanghai Scientific & Technical Publishers, 1991:160-183. (in Chinese)
. NICOLINI C, MALVEZZI M A,TOMASELLI A, et al. DNASER I : layout and data analysis[J]. IEEE Transactions on Nanobioscience, 2002, 6(1): 67-72.
. NAGARAJAN R, PETERSON CH A. Identifying spots in microarray images[J]. IEEE Transactions on Nanobioscience, 2002, 6 (1): 78-84.
. SHERPPARD C J R, GU M, MAO X Q. Three-dimensional optical transfer functions in a reflection-mode confocal scanning microscope[J]. Opt. Commun., 1991,81(5):281~284.
. HESS K,KEITH W,BAGGERLY A, et al. Microarrays: handling the deluge of data and extracting reliable information[J]. Trans. in Biotechnology, 2001, 11(19): 463-468.
. DRAZIC V. Dependence of two-and three-dimensional optical transfer functions on pinhole radius in a coherent confocal microscope[J].J. Opt. Soc. Am.(A),1992,9(5):725-731.
. 王立强,陆祖康,倪旭翔. 用于生物芯片荧光检测的共焦扫描装置 . 中国光学学会2004年学术大会论文集,2004,16:138-142. WANG L Q, LU Z K, NI X X. Scanning confocal system for fluorescence microarray analysis . Paper Collection of Chinese Optical Society2004 Symposium,2004,16:138-142.(in Chinese).
0