YE Dong, LIU Chang-ying, CHE Ren-sheng, et al. Dummy solid camera calibration technology using genetic algorithm[J]. Optics and precision engineering, 2006, 14(3): 485-489.
YE Dong, LIU Chang-ying, CHE Ren-sheng, et al. Dummy solid camera calibration technology using genetic algorithm[J]. Optics and precision engineering, 2006, 14(3): 485-489.DOI:
A dummy solid camera calibration method based on genetic algorithm was presented. Using the infrared LE moved with the CMM probe according to some distance
the solid calibration template was formed to estimate the initialization calibration parameters by the Singular Value Decomposition(SVD) algorithm. Finally
the genetic algorithm was used to optimize and determine all calibration parameters. The experimental results show that the inverse result error of calibration point is less than 0.04 mm
and the calibration method can resolve the problem of high-precision camera calibration
and also can meet the requirement of high-precision camera calibration in the field of large scale vision coordinate measurement.
关键词
Keywords
references
. ZHANG Y,OU ZH Y. A new linear approach for camera calibration[J]. Journal of Image and Graphics. 2001, 6(8): 727-731.
. MENG X Q,HU ZH Y. A new easy camera calibration technique based on circular points[J].Pattern Recognition. 2003, 36: 1155-1164.
. WENG J Y,COHEN P,HERNIOU M. Camera calibration with distortion models and accuracy evaluation[J]. IEEE Trans on Pattern Analysis and Machine Intelligence, 1992, 14(10): 965-980.
. HEIKKILA J,SILVEN O. A Four-step camera calibration procedure with implicit image correction[J]. IEEE Proceedings of Computer Vision and Pattern Recognition. 1997, 1106-1112.
. LIU CH Y,YU ZH J,CHE R SH,et al. Bundle adjustments CCD camera calibration based on collinearity equation . Chinese Journal of Mechanical Engineering,17:494-497.
. LIU CH Y,YE D,CHE R SH, etal. The study of CCD camera optimization calibration technique using genetic algorithm .Proceedings of Second International Symposium on Instrumentation Science and Technology (ISIST’2004), Xian, 2004. Harbin:Harbin Institute of Technology Press,2004.
. SONGDE M. A self-calibration technique for active vision system[J]. IEEE Transactions on Robotics and Automation, 1996, 12:114-120.
. KWON Y H,LINDLEY S L,SANDERS R H,et al. Applicability of the localized-calibration methods in underwater motion analysis . Proceedings of the XVIII International Symposium on Biomechanics in Sports, Hong Kong, China, 2000. Chinese University of Hong Kong Press,2000.