To realize the damage diagnosis of a optical fiber grating smart structure
the structual dynamic response signal was decomposed with the wavelet analysis method based on the vibration monitor of optical fiber grating smart structure.The wavelet packet decomposition was introduced
and the wavelet packet energy spectrum describing the damage character was used to identify the structual damage status. Then
six different damage circs were studied by experimental laminates
inculding the different degrees and the same location of structure damage
and different locations and the same degree of structure damage. The results show that the structure damage will lead to the increase of wavelet energy spectrum of some specifically frequency bands of the structure dynamic response signal
and the damage characters are sensitive to the damage degree
damage location and the degree from the damage to the sensor. In the experiment
this method can recognize the damage of 12 g weights and 30 cm from the optical fiber grating sensor
it is feasible to realize the structure on-line damage diagnosis.