推导出了正交光楔列阵(CSWA)聚焦系统的多光束干涉条纹主极大和两相邻主极大间的次极大间距公式
并根据广义惠更斯-菲涅耳衍射积分理论
通过数值计算证明了CSWA的小尺度不均匀性的变化规律与物理光学的公式符合。另外
提出改善小尺度不均匀性的两种方法:楔角偏差和离焦打靶技术。计算分析和实验研究表明
优化楔角偏差和离焦量的量值
即
pj
=2.0%
Z
=2 mm时
干涉主极大间隔与没加这两种技术时相比减小了6倍
小尺度的不均匀性得到了明显的改善。
The Separation of Interference Fringes of the Main Diffraction Maxima (SIFMDM) and the second maximum for Cross Segmented Wedge Array (CSWA) focus system were derived
and the change rules of the Small-scale Irradiation Non-uniformity(SSINU) were confirmed by numerical calculations based on the generalized Huygens-Fresnel diffraction integral theory. The two methods of reducing the SSINU
the Deviation of Wedge Angles (DWA) and the Off-focal Laser Radiation on the Target (OFLRT)
were proposed.Theoretical study and experimental results show they agree quite well. By both the DWA and the OFLRT
the SIFMDM can be reduced by 6 times and the SSINU is also improved obviously
when the DWAS and off-focal variables are optimized to
pj
=20%
Z
=2 mm.
DENG X, LIANG X, CHENG Z, et al.. Uniform illumination of large targets using a lens array [J]. Appl. Opt., 1986, 25(2): 377-381.[2] 张增宝, 翁志成, 丛小杰,等. 液晶背投影电视中蝇眼透镜阵列照明系统的设计 [J]. 光学精密工程,2002,10(2):126-129. ZHANG Z B, WENG ZH CH, CONG X J, et al.. Design on a fly lens array illumination system applied in LC rear projective TV [J]. Opt. Precision Eng., 2002,10(2):126-129.(in Chinese)[3] VILLENEUVE D M , ENRIGHT G D, BALDIS H A. Novel laser line focus geometry applied to X-ray lasers [J]. Opt. Commun., 1991, 81(2): 54-58.[4] 陈万年,王树森, 陈斌,等. 用于X射线激光实验研究的列阵柱面透镜线聚焦系统 [J]. 光学学报, 1991,11(9):829-833. CHEN W N, WANG SH S, CHEN B, et al.. Cylindrical lens array focus system fir X-ray laser experiments [J]. Acta Optica Sinica, 1991,11(9):829-833.(in Chinese)[5] 郑建洲, 蔡邦维, 吕百达,等. 二维正交光楔列阵大焦斑均匀照明光学系统的实验研究 [J]. 中国激光, 1997, 24(11):1008-1012. ZHENG J ZH, CAI B W, L B D, et al.. Experimental study of two-dimensional orthogonal segmented wedge array [J]. Chinese Journal of Lasers,1997,24(11):1008-1012. (in Chinese)[6] L B D, ZHENG J ZH, CAI B W, et al.. Tow-dimensional focusing of laser beams to provide uniform irradiation [J]. Opt. Commun., 1998, 149(4):19-26.[7] 郑建洲,于清旭,芦永军,等. 焦斑可调的透镜阵列均匀辐照光学系统[J]. 中国激光, 2007, 34(3):331-336. ZHENG J ZH, YU Q X, LU Y J, et al.. Improved lens arrays optical system with controllable focus width for uniform irradiation [J]. Chinese Journal of Lasers,2007,34(3):331-336. (in Chinese)[8] 郑建洲. 正交光楔列阵大尺度辐照均匀性的改善方法 [J]. 河北师范大学学报(自然科学版), 1999, 23(2):196-200. ZHENG J ZH. The improved methods of illumination uniformity of large-scale for the cross segmented wedge array (SWA) system [J]. Journal of Hebei Normal University (Natural Science), 1999, 23(2):196-200. (in Chinese)[9] 郑建洲,蔡邦维, 吕百达. 二维正交光楔列阵大焦斑均匀照明光学测试系统的研究 [J]. 光学学报,1997, 17(11):1581-1584. ZHENG J ZH, CAI B W, L B D. A testing system for two-dimensional orthogonal segmented wedge array applied to uniform illumination of large focal spot . Acta Optica Sinica. 1997, 17(11):1581-1584. (in Chinese)[10] LWENTHAL F, PRG A, BALMER J E. Reduction of small-scale intensity modulation in a line focus produced by a cylindrical lens array using polarization control and wedge angles [J]. Opt. Commun.,1997,135(1):7-13.[11] NAKANO H, MIYANAGA N, YAGI K, et al.. Partially coherent light generated by using single and multimode optical fibers in a high-power Nd: glass laser system [J]. Appl. Phys. Lett., 1993,63(5):580-582. [12] TSBAKIMOTO K, NAKATSUKA M, NAKANO H, et al.. Suppression of interference speckles produced by a random phase plate using a polarization control plate . Opt. Commun., 1992,91(1):9-12.[13] SKUPSKY S, SHORT R W, KESSLER T, et al.. Improved laser-beam uniformity using the angular dispersion of frequency-modulated light [J].J. Appl. Phys., 1989,66(8):3456-3462.[14] SEAN P R, JOHN A M, JOHN H K, et al.. Experimental investigation of smoothing by spectral dispersion [J]. J. Opt. Soc. Am. B, 2000, 17(9):1483-1489.[15] ZHOU S L, LIN Z Q, JIANG X J. Beam smoothing by lens array with spectral dispersion [J]. Opt. Commun., 2007, 272(1):186-191.