The research on the correction of the aberration in eyes with liquid crystal spatial light modulator[J]. Optics and precision engineering, 2009, 17(11): 2651-2656.
The research on the correction of the aberration in eyes with liquid crystal spatial light modulator[J]. Optics and precision engineering, 2009, 17(11): 2651-2656.DOI:
Objective: A adaptive optics system (AO) integrates human eye wave-front sensor components and correction components was built and tested. Method: The system uses a Hartman-Shack wave-front sensor (HS-WS) and liquid crystal spatial light modulator (LCSLM) for AO-correction of the dynamic aberrations of the human eye. Result: During testing with a 5D myopic human eye
the AO system corrected ocular aberrations to a residual RMS wave-front error of 0.013(=0.808 nm). Conclusion: The LCSLM can correct the aberration in eyes effectively
After AO correction the cone of the retina can be seen clearly.