浏览全部资源
扫码关注微信
1. 山西大学 物理电子工程学院,山西 太原 030006
2. 天津大学 精密仪器与光电子工程学院,天津 300072
收稿日期:2010-06-02,
修回日期:2010-07-05,
网络出版日期:2010-11-25,
纸质出版日期:2010-11-25
移动端阅览
乔晓艳, 王艳景, 李刚. 偏最小二乘法荧光光谱预测啶虫脒农药残留[J]. 光学精密工程, 2010,18(11): 2369-2374
QIAO Xiao-yan, WANG Yan-jing, LI Gang. Prediction of acetamiprid residues by fluorescence spectroscopy based on PLS method[J]. Editorial Office of Optics and Precision Engineering, 2010,18(11): 2369-2374
乔晓艳, 王艳景, 李刚. 偏最小二乘法荧光光谱预测啶虫脒农药残留[J]. 光学精密工程, 2010,18(11): 2369-2374 DOI: 10.3788/OPE.20101811.2369.
QIAO Xiao-yan, WANG Yan-jing, LI Gang. Prediction of acetamiprid residues by fluorescence spectroscopy based on PLS method[J]. Editorial Office of Optics and Precision Engineering, 2010,18(11): 2369-2374 DOI: 10.3788/OPE.20101811.2369.
为满足农药残留多组分含量测定的要求
对荧光光谱法测量农药残留得到的混合光谱进行分离
基于偏最小二乘法建立荧光光谱测量系统校正模型
并预测啶虫脒残留量。选择20个特征波长
采用交互验证方法
以预测残差平方和为评价指标
确定最优主成份数
获得了最佳分析模型。通过对预测集进行测试
滤纸带和西红柿表面啶虫脒残留浓度为100
220
450 mg/kg的预测值分别是101.45
222.91
440.08 mg/kg和98.67
208.56
419.22 mg/kg
预测值和真实值的相关系数分别达到0.996和0.988。实验显示
采用偏最小二乘法结合荧光光谱测定啶虫脒农药残留
具有快速、无损、测量精度高等特点
并表明该方法用于定量分析复杂多组分体系是有效的。
To achieve the detection of multi-component pesticide residues
the Partial Least Square(PLS) method was applied to establishing a calibration model of fluorescence spectral measurement systems
and to predict the pesticide residues of acetamiprid by separating the overlapped spectrum in fluorescence spectroscopy of pesticide residues.By taking the predicted residual error square sum as an evaluating criterion
twenty characteristic wavelengths were selected and then the optimal number of principal components and the optimal analysis model were determined by the cross verification method. According to the test of prediction sets (100
220
450 mg/kg)
predictive values of acetamiprid residues are 101.45
222.91 and 440.08 mg/kg on the surface of filter paper
and 98.67
208.56 and 419.22 mg/kg on the surface of tomato. The correlation coefficients between predictive values and true values respectively reach 0.996 and 0.988. The results demonstrate that the method using PLS in fluorescence spectral analysis for measuring the acetamiprid residue has good performance in shorter measuring time
nondestructive testing and higher accuracy and can effectively implement quantitive analysis for complex and multi-component systems.
<td valign='top'>[1]JIANG X S, LI D Y, XU X, YING Y B, et al.Immunosensors for Detection of Pesticide Residues [J].. Biosensors and Bioelectronics.2008,23:1577-1587<a href='http://dx.doi.org/10.1016/j.bios.2008.01.035' target='_blank'><img src='../../images/crossref.gif' width='41' height='15' border='0' /><td valign='top'>[2]JOSE M C, ANA V, GUILLERMO S M, et al.. Pesticide residue analysis by RPLC-GC in Lycopene and other carotenoids obtained from tomatoes by supercritical fluid extraction[J]. Food Chemistry, 2009,113(1):280-284.<td valign='top'>[3]TING K C, TAMASHIRO G S. Off-line high-performance liquid chromatography and solid-phase extraction clean-up for confirmation of pesticide residues in fresh produce by gas chromatography-mass spectrometry [J].Journal of Chromatography.1996,754:455-462<a href='http://dx.doi.org/10.1016/S0021-9673(96)00374-3' target='_blank'><img src='../../images/crossref.gif' width='41' height='15' border='0' /><td valign='top'>[4]JOSE M C, ANA V, GUILLERMO S M, et al.Pesticide residue analysis by RPLC-GC in lycopene and other carotenoids obtained from tomatoes by supercritical fluid extraction[J].. Food Chemistry.2009,113:280-284<a href='http://dx.doi.org/10.1016/j.foodchem.2008.07.010' target='_blank'><img src='../../images/crossref.gif' width='41' height='15' border='0' /><td valign='top'>[5]DOU Y,ZOU T T ,LIU T, et al.. Calibration in non-linear NIR spectroscopy using principal component artificial neural networks [J]. Molecular and Biomolecular Spectroscopy, 2007,68(5):1201-1206.<td valign='top'>[6]王忠东,闫铁,王宝辉. 适于土壤中农药检测的荧光光纤系统[J]. 光学 精密工程,2008,16(7):1209-1212. WANG ZH D, YAN T, WANG B H. Fiber-optic fluorescence measuring system suitable for pesticide in soil[J]. Opt. Precision Eng., 2008,16(7):1209-1212.(in Chinese)<td valign='top'>[7]肖琳,何大卫. PLS回归方法及其医学应用[J]. 中国卫生统计,2004,19(2):76-79. XIAO L, HE D W. PLS regression and its application in medicine [J]. Chinese Journal of Health Statistics, 2004,19(2):76-79. (in Chinese)<td valign='top'>[8]郭志明,赵杰文,陈全胜,等. 特征谱区筛选在近红外光谱检测茶叶游离氨基酸含量中的应用[J]. 光学 精密工程,2009,17(8):1840-1844. GUO ZH M, ZHAO J W, CHEN Q SH, et al.. Application of selecting wavelength regions to determination of free amino acid content in tea by FT-NIR spectroscopy [J].Opt. Precision Eng., 2009,17(8):1840-1844. (in Chinese)<td valign='top'>[9]王忠东,王玉田. 常用农药荧光特性的理论与实验[J]. 发光学报,2005,26(1):120-124. WANG ZH D,WANG Y T. Theoretical and experimental study on fluorescence characteristics of common pesticides[J].Journal of Luminescence, 2005,26(1):120-124.(in Chinese)<td valign='top'>[10]王动民,金尚忠,陈华才,等. 棉-涤混纺面料中棉含量的近红外光谱分析[J]. 光学 精密工程,2008,16(11):2052:2054 WANG D M,JIN SH ZH,CHEN H C, et al.. Quantitative analysis of cotton content in cotton-terylene textile by near infrared technique[J]. Opt. Precision Eng., 2008,16(11):2052-2054. (in Chinese)
0
浏览量
529
下载量
6
CSCD
关联资源
相关文章
相关作者
相关机构