浏览全部资源
扫码关注微信
国防科技大学 光电科学与工程学院,湖南 长沙,410073
收稿日期:2010-10-08,
修回日期:2010-10-30,
网络出版日期:2011-02-22,
纸质出版日期:2011-02-22
移动端阅览
王红岩, 张煊喆, 李强, 肖楠, 华卫红, 司磊. 氮稀释高效电激励连续波HF/DF化学激光器[J]. 光学精密工程, 2011,19(2): 304-309
WANG Hong-yan, Zhang Xuan-zhe, LI Qiang, XIAO Nan, HUA Wei-hong, SI Lei. Efficient nitrogen diluted discharge-driven continuous wave HF/DF chemical lasers[J]. Editorial Office of Optics and Precision Engineering, 2011,19(2): 304-309
王红岩, 张煊喆, 李强, 肖楠, 华卫红, 司磊. 氮稀释高效电激励连续波HF/DF化学激光器[J]. 光学精密工程, 2011,19(2): 304-309 DOI: 10.3788/OPE.20111902.0304.
WANG Hong-yan, Zhang Xuan-zhe, LI Qiang, XIAO Nan, HUA Wei-hong, SI Lei. Efficient nitrogen diluted discharge-driven continuous wave HF/DF chemical lasers[J]. Editorial Office of Optics and Precision Engineering, 2011,19(2): 304-309 DOI: 10.3788/OPE.20111902.0304.
提出使用低温吸附泵代替传统的机械真空泵和洗消装置的设想
以大幅降低电激励连续波HF/DF化学激光器的体积和重量。针对该技术需将常用的氦稀释剂替换为氮稀释剂从而引起激光器效率大幅下降的问题
对超音速阵列喷管激光器进行了研究。为提高氮稀释剂激光器效率
研制了周期4 mm间隔排列的狭缝-列孔超音速阵列喷管
以代替传统的单通道燃料流横向注入增益发生器。以HF激光为例的实验表明:前者在放电管电极间距仅为后者一半的条件下
单管激励出的光功率由25 W提高到90 W
电光转换效率由0.8%提升到5.9%
燃料利用效率提高近4倍
从仅为氦稀释剂运转情形的一半变为略高于氦稀释剂情形。这些结果表明
通过专门研制的超音速阵列喷管大幅提高了氮稀释电激励连续波HF/DF激光器的效率。
A cryogenic adsorption technique was presented to replace the machinery pump and exhaust processing system
which could provide a possible way to greatly suppress the size of a discharge-driven CW HF/DF chemical laser.As the nitrogen diluent must be used instead of helium for the cryogenic adsorption pump
the efficiency of HF/DF chemical laser would be lowered down greatly. To solve the problem
a periodically arranged supersonic nozzle array composed of slit and conical holes with a 4 mm period was developed to replace the traditional single slit transverse sonic fuel injecting gain generator. Experimental results with HF laser demonstrates that the laser output and electrical-optical efficiency by designed supersonic nozzle array have been increased from 25 W to 90 W
and 0.8% to 5.9%
respectively.Furthermore
the fuel specific efficiency has a nearly fourfold increase
which is slightly higher than that from the helium diluen. Obtained results prove that the efficiency of the nitrogen diluted discharge-driven CW HF/DF chemical laser can be greatly improved by using the devel- oped supersoinc nozzle array.
江腾蛟,黄伟,齐文宗,等. 表面热透镜技术测量3.8 m和2.8 m激光薄膜的微弱吸收 [J]. 强激光与粒子束,2004,16(21):1497-1500. JIANG T J, HUANG W, QI W Z, et al.. Thin film weak absorption of 3.8 m and 2.8 m laser measured by surface thermal lensing technique[J]. High Power Laser and Particle Beams, 2004,16(21):1497-1500. (in Chinese)[2] 王红岩,袁圣付,李强,等. 用于大气吸收测量的小型电激励连续波DF/HF选线化学激光器 [J]. 中国激光,2008,35(7):997-1000. WANG H Y, YUAN SH F, LI Q, et al.. A discharge driven continuous wave single line DF/HF chemical laser for atmospheric absorption measurement [J]. Chinese Journal of Lasers, 2008,35(7):997-1000.(in Chinese)[3] WALDO R E, BETTS J A, HARTLOVE J S. New method for HF small signal gain measurements .32th AIAA Plasmadynamics and lasers conference, 11-14 June 2001.[4] WISNIEWSKI C F, HEWETT K B, MANKE G C II, et al.. Small signal gain measurement in a small scale HF overtone laser[J]. Applied Physics Letters, 2003,77(2):337-342.[5] ZIMMERMAN J W, BENAVIDES G F, PALLA A D, et al.. Gain recovery in an electric oxygen iodine laser[J]. Applied Physics Letters, 2009,94(2):021129.[6] DUO L P, TANG S K, YU H J, et al.. DC discharge characteristics and fluorine atom yield in NF3/He [J]. Chineses Optics Letters, 2006,4(3):170-172.[7] JHA A R. Infrared Technology, Applications to Electro-optics, Photonic Devices, and Sensors[M]. John Wiley& Sons inc,2000.[8] 赵振国.吸附作用应用原理[M]. 北京:化学工业出版社,2005. ZHAO Z G.Application Principle of Adsorption [M].Beijing: Chemical Industry Press,2005.[9] GROSS R W F,BOTT J F. Handbook of Chemical Lasers[M]. John Wiley & Sons, 1976.[10] BOREISHO A S, BARKAN A B, VASILEV D N, et al.. Highly efficient cw chemical oxygen iodine laser with transonic iodine injection and a nitrogen buffer gas[J]. Quantum Electronics,2005,35(6):495-503.[11] 房本杰.以氮气为载气的氧碘化学激光器的研究 . 大连:大连化学物理研究所,2004. FANG B J. Study on a chemical oxygen iodine laser using nitrogen buffer gases . Dalian:Dalian Institute of Chemical Physics,2004.(in Chinese)[12] 李永锋,凌军,刘燕珍,等. 高比表面积活性炭研究进展[J]. 热带作物学报,2008,29(3):396-401. LI Y F,LIN J,LIU Y ZH,et al.. Research advances in activated carbon with high specific surface area[J].Chinese Journal of Tropical Crops,2008,29(3):396-401.(in Chinese)[13] HINCHEN J J. Operation of a small single mode stable cw hydrogen fluoride laser[J].Journal of Applied Physics,1974,45(4):1818-1821.[14] SPENCER D J, BEGGS J A, MIRELS H. Small scale cw HF(DF) chemical laser [J]. Journal of Applied Physics, 1977,48(3):1206-1211.[15] JEFFERS W Q M. Scalable overtone HF chemical laser:United States,4,670,582 .1988-7-26.[16] SENTMAN L H, THEODOROPOULOS P, NGUYEN T, et al.. An economic supersonic cw HF laser testbed . AIAA,1898, 1989.[17] 文备,李文煜,王红岩,等. 电激励连续波HF/DF激光器放电参数的优化[J]. 激光与光电子学进展,2010, 47(5):051404. WEN B, LI W Y, WANG H Y. Optimization of discharge parameters on discharge driven cw HF/DF chemical laser [J]. Laser & Optoelectronics Progress, 2010,47(5):051404.(in Chinese)[18] 王红岩,袁圣付,张鹏,等. 电激励红外多波段化学激光器中稀释剂注入方式对激光输出的影响[J]. 中国激光,2005,17(3):339-342. WANG H Y, YUAN SH F, ZHANG P, et al.. Effects of two different diluent injecting methods on a discharge excited infrared multi-band chemical laser[J]. High Power Laser and Particle Beams, 2005,17(3):339-342 .(in Chinese)
0
浏览量
660
下载量
4
CSCD
关联资源
相关文章
相关作者
相关机构