ZHAO Li-ping, LI Xiang, FANG Zhong-ping. 塑料眼镜内外缺陷检测的全内反射照明技术[J]. 光学精密工程, 2011,19(9): 2247-2254
ZHAO Li-ping, LI Xiang, FANG Zhong-ping. TIR illumination technology for defect inspection of plastic ophthalmic lenses[J]. Editorial Office of Optics and Precision Engineering, 2011,19(9): 2247-2254
ZHAO Li-ping, LI Xiang, FANG Zhong-ping. TIR illumination technology for defect inspection of plastic ophthalmic lenses[J]. Editorial Office of Optics and Precision Engineering, 2011,19(9): 2247-2254 DOI: 10.3788/OPE.20111909.2247.
Currently most plastic lenses and optical surfaces are still inspected directly by eyes by inspectors. In this paper
a Total Internal Reflection (TIR) illumination based dark-field inspection is analyzed and designed to enhance the visibility and contrast of the defects on the two surfaces of and inside the plastic lenses
and a lens inspection prototype is developed. Some trial testings have been conducted with the prototype
and the testing results are compared with those obtained from manual inspection directly operated by inspectors. The TIL dark-field inspection technique and feasibility to detect the popular defects of plastic ophthalmic lenses are verified and evaluated.
关键词
Keywords
references
http://www.fmc.rpi.edu/research.html.[2] DONG-SEON Y,SEUNG-WOO K. Rapid defect inspection of display device with optical spatial filtering[J]. International Journal of the Korean Society of Precision Engineering, 2000,1(1):56-61.[3] THOMAS W, PETER P.Fully automatic inspection of mobil phone display lenses[J].Kunststoffe Plast Europe, 2003,1:66-68.[4] NAKAYAMA.Optical member inspecting apparatus and method of inspection thereof US patent, No. 6,148,097[P].2000-11-14.[5] VAEZ-IRAVANI.Defect detection system US Patent 6,862,096[P].2005-03-01.