为使神光Ⅲ主机装置的打靶精度达到30 m
本文以稳定性指标为前提设计了该装置的靶场编组站
并对编组站刚架和传输反射镜组件进行了优化。采用钢筋混凝土结构支撑编组站刚架
在编组站刚架主框架内增加斜撑
以减小并合理分布编组站刚架的质量载荷
同时对局部的横梁增加人字形斜撑。设计了反射镜架且使其基频远高于编组站刚架基频以抑制编组站反射镜在随机宽频振动激励下的角度漂移。对靶场结构有限元(FEA)模型的力学分析表明
编组站中87%的传输反射镜的角度漂移低于0.48 rad
根据靶场系统中各元件漂移对光路定位误差的影响公式进行分析
结果显示编组站反射镜角度漂移可以满足靶场各单条光路定位误差不超过12.9 m的稳定性指标
证明所设计的神光III主机装置编组站可以满足相应的稳定性要求。
To assure the pointing accuracy in a shooting target to be better than 30 m for the Shen Guang Ⅲ(SGⅢ)facility
the switchyard of target area for the facility was designed and the rigid frame and transport mirrors in the switchyard were optimized to improve their stability. In design
the reinforced concrete was used to support the switchyard
and the tilted supports were added in the steel frame of switchyard to decrease and distribute the mass load reasonably.Furthermore
the herringbone supports were firmed to local horizontal beams. The transport mirror supports were also designed
in which their foundational frequencies were much higher than that of the swichyard. By above ways
the angle shifts of transmission mirrors in random broadband vibration can be suppressed successfully. The mechanical analysis of range structure by Finite Element Analysis(FEA) indicates that 87% of transport mirrors show their angle shifts less than 0.48 rad. According to the relation between the rotation drifts of the optics components and the positioning errors of optical path
it can be seen that the rotation drifts of the transmission mirrors could meet the stability requirements for the positioning error of each single optical path not more than 12.9 m.
彭翰生, 张小民, 范滇元, 等. 高功率固体激光装置的发展与工程科学问题 [J]. 中国工程科学, 2001, 3(3): 1-8. PENG H SH, ZHANG X M, FAN D Y, et al.. Status of high-power solid-state lasers and engineering science[J]. Engineering Science, 2001, 3(3): 1-8. (in Chinese)[2] 师智全, 彭翰生, 粟敬钦. ICF驱动器定位误差估计[J]. 强激光与粒子束, 2002, 14(2): 275-278. SHI ZH Q, PENG H S, SU J Q. Beam positioning error budget in ICF driver[J]. High Power Laser and Particle Beams, 2002, 14(2): 275-278. (in Chinese)[3] TIETBOHL G L, SOMMER S C. Stability design considerations for mirror support systems in ICF lasers . Livermore: Lawrence Livermore National Laboratory, 1996.[4] FOLEY R J. Design of the target area for the national ignition facility . Livermore: Lawrence Livermore National Laboratory, 1998.[5] TRUMER D J. Stability of optical elements in the NIF target area building . Livermore: Lawrence Livermore National Laboratory, 1998.[6] SOMMER S C, BLISS E S. Beam positioning . California: Lawrence Livermore National Laboratory, 1998.[7] 傅学农, 陈晓娟, 吴文凯, 等. 大口径反射镜组件设计及稳定性研究[J]. 光学 精密工程, 2008, 16(2): 179-183. FU X N, CHEN X J, WU W K, et al.. Design of large aperture mirror support and its stability[J]. Opt. Precision Eng., 2008, 16(2): 179-183. (in Chinese)[8] 乔战峰, 赵东峰, 戴亚平, 等. "神光-II"第九路终端光学系统稳定性分析[J]. 强激光与粒子束, 2006, 18(3): 419-422. QIAO ZH F, ZHAO D F, DAI Y P, et al.. Stability analysis of final optical system of additional beam in "Shenguang-II laser facility"[J]. High Power Laser and Particle Beams, 2006, 18(3): 419-422. (in Chinese)[9] 徐元利, 吴文凯, 陈学前,等. ICF装置靶场结构总体稳定性设计[J]. 强激光与粒子束, 2009, 21(10): 1485-1488. XU Y L, WU W K, CHEN X Q, et al.. Structural systemic stability design of inertial confinement fusion facility target area[J]. High Power Laser and Particle Beams, 2009, 21(10): 1485-1488. (in Chinese)[10] 陈学前, 冯加权, 徐元利. 基于有限元分析的大型固体激光器稳定性指标重分配[J]. 强激光与粒子束, 2010, 22(5): 1073-1076. CHEN X Q, FENG J Q, XU Y L. Stability reallocation of large solid state laser based on finite element analysis[J]. High Power Laser and Particle Beams, 2010, 22(5): 1073-1076. (in Chinese)[11] CRANDALL S H, MARK W D. Random Vibration in Mechanical Systems[M]. New York:Academic Press, 1963.