浏览全部资源
扫码关注微信
沈阳师范大学 物理科学与技术学院
收稿日期:2012-11-29,
修回日期:2013-01-05,
纸质出版日期:2013-02-15
移动端阅览
刘丽丽 黄涛 蔡敏 高明 封文江. 大视场液晶自适应视网膜成像系统[J]. 光学精密工程, 2013,21(2): 301-307
LIU Li-li HUANG Tao CAI Min GAO Ming FENG Wen-jiang . Retinal imaging system with large field of view,based on liquid crystal adaptive optics[J]. Editorial Office of Optics and Precision Engineering, 2013,21(2): 301-307
刘丽丽 黄涛 蔡敏 高明 封文江. 大视场液晶自适应视网膜成像系统[J]. 光学精密工程, 2013,21(2): 301-307 DOI: 10.3788/OPE.20132102.0301.
LIU Li-li HUANG Tao CAI Min GAO Ming FENG Wen-jiang . Retinal imaging system with large field of view,based on liquid crystal adaptive optics[J]. Editorial Office of Optics and Precision Engineering, 2013,21(2): 301-307 DOI: 10.3788/OPE.20132102.0301.
设计了大视场眼底自适应成像系统,用于扩大现有视网膜自适应成像系统的视场。对人眼等晕角视场下的自适应像差校正成像进行分析,确定了波前探测与成像校正两个过程对视场的不同要求。在共光源像差探测及成像光学系统中,采用切变视场光阑的方式先后在波前探测和自适应校正成像过程中进行小-大视场切换,避免了大视场中眼波像差探测失真问题,使成像区域由200 μm扩展到500 μm。利用人眼等晕角大视场使眼底液晶自适应成像系统在不降低成像质量的前提下将成像区域扩展了2.5倍,大幅提升了该自适应成像系统在临床上应用的可行性。
A retinal imaging Adaptive Optical(AO) system with a large Field of View(FOV) was designed to expand the FOV of the retinal image of liquid crystal AO system. Based on analysis of the AO retinal imaging system under an isoplanatic angle
it pointed out that the FOV for wave-front detection should be smaller than a half isoplanatic angle for precise wave-front detection and the half FOV should not be larger than the isoplanatic angle in imaging. A coaxial wave-front detection and optical imaging system was fabricated
meanwhile
an adjustable pupil was used to switch the different FOVs for wave-front detection and imaging
respectively. After adaptive optical wave front correction
the wave-front error is significantly reduced and the FOV for imaging is enlarged from a diameter of 200 μm to 500 μm without any harmful effect on imaging quality. By utilizing an adjustable pupil in the system based on the isoplanatic angle
the retinal image FOV has increased by 2.5 times as compared with that of existing AO system. The applicability of the system on clinical practice is increased a lot by this research.
LIANG J, WILLIAMS D R. Aberrations and retina image quality of the normal human eye [J]. J. Opt. Soc. Am. A, 1997, 14: 2873-2883.[2]HU L F, LI X,LIU Y J, et al.. Phase-only liquid-crystal spatial light modulator for wave-front correction with high precision [J]. Optics Express, 2004, 12:6403-6409.[3]曹召良, 李小平, 宣丽,等. 液晶自适应光学的研究进展[J]. 中国光学, 2012,5(1):12-19.CAO ZH L, LI X P, XUAN L, et al.. Recent progress in liquid crystal adaptive optical techniques[J]. Chinese Optics, 2012,5(1):12-19. (in Chinese)[4]LI CH,XIA M L, LI D Y,et al.. High-precision open-loop adaptive optics system based on LC-SLM [J]. Optics Express, 2009, 17: 10774-10781.[5]VARGAS-MARTIN F, PRIETO P,ARTAL P. Correction of the aberrations in the human eye with liquid crystal spatial light modulators: limits to the performance [J]. J. Opt. Soc. Am. A. 1998, 15: 2552-2562.[6]FUSCO T, CONAN J M,MICHAU V,et al.. Isoplanatic angle and optimal guide star separation for multiconjugate adaptive optics [J].SPIE 2000, 4007:1044.[7]陈浩, 宣丽, 胡立发,等. 望远镜的紧凑型闭环液晶自适应光学系统设计[J].液晶与显示, 2010, 25(3):379-385.CHEN H, XUAN L, HU L F, et al.. Design on compact type closed-loop liquid crystal adaptive optical system for telescope[J]. Chinese Journal of Liquid Crystals and Displays, 2010, 25(3):379-385. (in Chinese)[8]周仁忠,阎吉祥. 自适应光学理论. [M]. 第一版. 北京:北京理工大学出版社,1996:109-115.ZHOU R ZH,YAN J X. Theory of Adaptive Optics [M]. 1st Ed. Beijing:Beijing Institute of Technology Press,1996:109-115. (in Chinese)[9]BEDGGOOD P,DAABOUL M, et al.. Characteristics of the human isoplanatic patch and implications for adaptive optics retinal imaging [J]. Journal of Biomedical Optics,2008,13:024008.[10]张强,姜文汉. 光子计数型Shack-Hartmann波前探测器研究[J]. 光学 精密工程,1996, 4(5) :90-94.ZHANG Q, JIANG W H. The research of Shack-Hartmann wave-front sensor in photo counting condition [J]. Opt. Precision Eng., 1996, 4 (5): 90-94. (in Chinese)[11]钮赛赛,沈建新,等. 人眼像差探测哈特曼波前传感器的质心优化[J]. 光学 精密工程, 2011, 19(12):316-324.NIU S S, SHEN J X, et al.. Centroid optimization of Hartmann-Shack wave-front sensor for human eye aberration detection [J]. Opt. Precision Eng., 2011, 19(12):316-324. (in Chinese)[12]程少园, 曹召良,等.用夏克-哈特曼探测器测量人眼波前像差[J]. 光学 精密工程, 2010, 18(5): 1060-1067.CHENG SH Y, CAO ZH L,et al.. Measurement of wavefront aberrations of human eyes with Shack-Hartmann wavefront sensor [J]. Opt. Precision Eng., 2010, 18(5):1060-1067. (in Chinese)
0
浏览量
618
下载量
4
CSCD
关联资源
相关文章
相关作者
相关机构