CHEN Hao XUAN Li HU Li-fa CAO Zhao-liang MU Quan-quan. Steady measurement of atmospheric turbulence coherence length[J]. Editorial Office of Optics and Precision Engineering, 2013,21(4): 911-918
CHEN Hao XUAN Li HU Li-fa CAO Zhao-liang MU Quan-quan. Steady measurement of atmospheric turbulence coherence length[J]. Editorial Office of Optics and Precision Engineering, 2013,21(4): 911-918 DOI: 10.3788/OPE.20132104.0911.
is measured by traditional Differential Image Motion Monitor(DIMM) method
it is difficult to obtain a stable r
0
value due to limitation of light spot pairs. Therefore
this paper proposes a statistical method to increase the statistical number of light spot pairs from one on a wavefront to twelve aligned in a square
and completes the statistics on a SHWFS light spot array captured by the Shack-Hartmann wavefront detector. The method spatially increases the statistical number of samplings and the spatial symmetry of r
0
measurement
so it decreases the statistical time greatly. The experiments show that only three hundred of wavefront samples gotten in 300 ms are enough to obtain the r0 with a variation less than 3%. The presented method solves the large error problem in the traditional r
0
measurement for long time
and has contributed to the improvement of imaging accuracy of adaptive optical systems for ground-based telescopes.
关键词
Keywords
references
VALLEY G C.Isoplanatic degradation of tilt correction and short-term imaging systems [J].Appl.Opt.,1980,19:574.[2]BABCOCK H W.The possibility of compensating astronomical seeing [J]. Publ Astron. Soc. Pac., 1953, 65:229-236.[3]陈浩,宣丽,胡立发,等.1 200 mm望远镜开环液晶自适应光学系统设计[J].光学 精密工程,2010,18(1):29-36. CHEN H,XUAN L,HU L F,et al..Design on open-loop liquid crystal adaptive optical system for 1 200 mm telescope [J]. Opt. Precision Eng., 2010,18(1):29-36. (in Chinese)[4]陈浩,宣丽,胡立发,等.望远镜的紧凑型闭环液晶自适应光学系统设计[J].液晶与显示,2010,25(3):379-385. CHEN H,XUAN L,HU L F,et al..Design on compact type closed-loop liquid crystal adaptive optical system for telescope[J].Chinese Journal of Liquid Crystals and Displays., 2010,25(3):379-385. (in Chinese)[5]SLAVIN A C,WELLS A L,FUGATE R Q,et al..A comparison of three methods of measuring the atmospheric coherence length[C].Proc.SPIE,1997,3125:241-249.[6]DAVID D,BOB P,BRIAN S.Atmospheric structure function measurement with a Shack- Hartmann wavefront sensor [J].Optics Letters,1992,17(24):1737-1739.[7]TRAVOUILLON T,ASHLEY M C B,BURTON M G,et al..Automated Shack-Hartmann seeing measurements at the south pole[J].A