针对基于光学手段实现的传统光学联合变换相关器不适应空间环境等问题,对传统相关器进行了改进和试验验证。首先,采用完全电子学手段替代采用光学器件实现的方法解决了联合变换相关器适应空间环境的问题。然后,在联合变换过程中加入自相关运算,消除了零级衍射峰的影响,并引入过采样离散傅里叶变换方法提升相关器的测量精度。最后,采用精密直线导轨开展静态测试试验,验证了改进后的联合变换相关器的性能。静态测试试验表明:对于亚像元级的微小位移量,改进后的联合变换相关器测量误差均方根(RMS)值为0.22 pixel。改进后的联合变换相关器显示了良好的空间环境适应性和较好的可实现性,其精度基本满足空间相机像移补偿的要求。
As traditional joint transform correlators based on space light modulators can not adapt to the radioactive environment in space
a new correlator implemented by an electronic processor was introduced and testified. First
the traditional optical device was replaced by a digital processor to allow the new correlator to adapt to the radioactive environment. Then
a self-correlation calculation was added to the joint transform processing to eliminate the influence of zero-level diffraction
and the over-sampled discrete Fourier transform method was introduced to increase the measurement precision. Finally
the static measurement with a linear platform was performed to testify the improved joint transform correlator. Experimental results indicate that the measuring precision of the system on subpixel displacement is within 0.22 pixel(Root Mean Square
RMS). The improved joint transform correlator is good at both space environment adaptability and realization
its measurement precision can satisfy the system requirements of satellite cameras for the image motion compensation
and has a good application prospect.
韩昌元. 近代高分辨地球成像商业卫星[J]. 中国光学与应用光学, 2010,3(2):201-208. HAN CH Y. Recent earth imaging commercial satellites with high resolutions [J]. Chinese Journal of Optics and Applied Optics, 2010,3(3):201-208. (in Chinese)
韩昌元. 高分辨力空间相机的光学系统研究[J]. 光学 精密工程, 2008,16(11):2164-2172. HAN CH Y. Study on optical system of high resolution space camera [J]. Opt. Precision Eng., 2008,16(11): 2164-2172. (in Chinese)
耿文豹,翟林培,丁亚林. 振动对光学成像系统传递函数影响的分析[J]. 光学 精密工程, 2009,17(2):314-320. GENG W B, ZHAI L P, DING Y L. Analysis of influence of vibration on transfer function in optics imaging system [J]. Opt. Precision Eng., 2009,17(2): 314-320. (in Chinese)
TCHERNYKH V, DYBLENKO S, JANSCHEK K, et al.. Airborne test results for a smart pushbroom imaging system with optoelectronic image correction [J]. SPIE, 2004, 5234:550-559.
JANSCHEK K,TCHERNYKH V, DYBLENKO S, et al.. Compensation of focal plane image motion perturbations with optical correlator in feedback loop [J]. SPIE, 2004, 5570:280-288.
葛鹏,陈跃庭,李奇,等. 欠曝光下光学联合变换相关器位移探测技术的稳健性研究[J]. 光学学报,2009,29(7):1796-1800. GE P, CHEN Y T, LI Q, et al.. Robustness study of motion detection based on joint transform correlator without enough illumination[J]. Acta Optica Sinica, 2009,29(7):1796-1800. (in Chinese)
樊超,李英才,傅洪亮,等. 离焦对光学相关法测量空间相机像移精度的影响[J]. 光学学报, 2011,31(10): 1028002-1-7. FAN CH, LI Y C, FU H L, et al.. Influence of defocusing on measurement accuracy of image motion of space camera[J]. Acta Optica Sinica, 2011,31(10):1028002-1-7. (in Chinese)
樊超,李英才,傅洪亮,等. 光学相关法测量空间相机像移的性能研究[J]. 光学学报, 2011,31(7): 0712006-1-5. FAN CH, LI Y C, FU H L, et al.. Research on measurement method of image motion of space camera based on optical correlator[J]. Acta Optica Sinica, 2011,31(7):0712006-1-5. (in Chinese)
易红伟,赵惠,汶德胜,等. 联合变换相关器像移测量静态仿真实验分析[J]. 光学学报, 2010,30(12): 3471-3475. YI H W, ZHAO H, WEN D SH, et al.. Static simulation experiment of image motion measurement based on optical joint transform correlator[J]. Acta Optica Sinica, 2010,30(12): 3471-3475. (in Chinese)
LIN G, LI Q, FENG H J, et al.. Experiments research on motion detection accuracy of joint transform correlator [J]. SPIE, 2012, 8561:85610W-1-8.
GE P, LI Q, FENG H J, et al.. Displacement measurement using phase-encoded target joint transform correlator [J]. Optical Engineering, 2011, 50(3):038201-1-11.
ZHAO H, YI H W, LI Y C, et al.. Experimental research on image motion measurement using optical joint transform correlator for space camera application [J]. SPIE, 2010, 7830: 78301D-1-8.
GERALD C H. CCD Arrays,Cameras and Displays[M]. Bellingham: SPIE Optical Engineering Press,1998.
王玉荣,徐鹏,王青圃. 光电混合联合变换相关器中各元器件结构参数之间的关系[J]. 光学 精密工程,2005,13(3):376-384. WANG Y R, XU P, WANG Q P. Relationship between parameters in hybrid optical/electronic joint transforms correlator [J]. Opt. Precision Eng., 2005,13(3): 376-384. (in Chinese)
0
浏览量
715
下载量
2
CSCD
关联资源
相关文章
相关作者
相关机构