韩启金, 傅俏燕, 张学文等. 高分一号卫星宽视场成像仪的高频次辐射定标[J]. 光学精密工程, 2014,22(7): 1707-1714
HAN Qi-jin, FU Qiao-yan, ZHANG Xue-wen etc. High-frequency radiometric calibration for wide field-of-view sensor of GF-1 satellite[J]. Editorial Office of Optics and Precision Engineering, 2014,22(7): 1707-1714
韩启金, 傅俏燕, 张学文等. 高分一号卫星宽视场成像仪的高频次辐射定标[J]. 光学精密工程, 2014,22(7): 1707-1714 DOI: 10.3788/OPE.20142207.1707.
HAN Qi-jin, FU Qiao-yan, ZHANG Xue-wen etc. High-frequency radiometric calibration for wide field-of-view sensor of GF-1 satellite[J]. Editorial Office of Optics and Precision Engineering, 2014,22(7): 1707-1714 DOI: 10.3788/OPE.20142207.1707.
为实现高分一号卫星宽视场成像仪的实时辐射定标,准确获取成像仪在轨暗电流噪声引起的偏移量信息,提出了高频次辐射定标方法,并分析了方法的可靠性和测算精度。介绍了卫星遥感器在轨辐射定标原理。以敦煌辐射校正场为实验区,利用该场地历史光谱数据和实时气象观测数据确定了高频次定标的数据基准。基于成像仪夜间大面积海洋场景数据测算了偏移量信息,即在无辐射能量输入的条件下,测算成像仪自身暗电流噪声引起的输出数值。然后,利用地面参考基准数据和偏移量信息,实现了高分一号卫星宽视场成像仪的在轨定标。最后,分析和检验了高频次定标方法的不确定性和定标结果的可靠性。结果表明:高分一号卫星宽视场成像仪高频次定标的不确定度小于5.3%;基于该定标结果获取的辐亮度产品与基于官方定标结果获取的辐亮度总体相对偏差小于5.6%;基于夜间海洋场景计算的定标截距(即偏移量)更接近于理论设计值。该方法可用于高分一号卫星宽视场成像仪的在轨定标和暗电流噪声定期检测。
To realize real-time radiometric calibration of a wide field-of-view sensor on the GF-1 satellite and to obtain offset information caused by dark-noise signals of the WFV sensor
a high-frequency calibration method was established and the reliability and precision of this method were researched and analyzed.Firstly
the in-flight radiometric calibration theory was introduced
and the reference benchmark of calibration data was established by using historical spectral reflectance data and real-time atmosphere profiles of Dunhuang test site.The offset was calculated based on a nighttime offing observing image
which is the digital number signal output from the sensor in the condition of naught radiance input.Then the WFV sensor of GF-1 satellite was calibrated by using the reference data from ground and the offsets prepared.Finally
the uncertainty of this method and accuracy of calibration results were analyzed and validated.Experimental results indicate that the uncertainty of high-frequency calibration of WFV sensor is less than 5.3%
and the difference between radiance based on high-frequency calibration coefficients and radiance with official promulgation publicized results is lower than 5.6%.The offset
calibration intercept
calculated with nighttime sea image accords with the theoretical design value
meanwhile
the calibration method can satisfy the requirement of the in-flight calibration and dark-noise detection of the WFV sensor on GF-1 satellite periodically.
顾行发,田国良,李小文,等. 遥感信息的定量化[J]. 中国科学E辑:信息科学,2005,35(增刊Ⅰ):1-10. GU X F,TIAN G L,LI X W,et al. Quantitative of remote sensing information[J]. Science in China Ser. E:Information Sciences,2005,35(suppl. Ⅰ):1-10. (in Chinese)
梁顺林. 定量遥感[M]. 范文捷译. 北京:科学出版社,2009. LIANG SH L. Quantitative remote sensing of land surfaces [M]. FAN W J Translated. Beijing:China Science Press,2009. (in Chinese)
董建婷,张旭辉. 光学遥感器光电信号处理系统的空间辐射效应研究[J]. 航天返回与遥感,2009,30(4):57-63. DONG J T,ZHANG X H. Space radiation effects on photoelectric signal processing system of optical remote sensor[J]. Spacecraft Recovery & Remote Sensing,2009,30(4):57-63. (in Chinese)
BIGGAR S F. In-flight methods for satellite payload absolute radiometric calibration. Dissertaion of Ph D,Tucson:The University of Arizona,USA,1990.
高海亮,顾行发,余涛,等. 星载光学遥感器可见光近红外通道辐射定标研究进展[J]. 遥感信息,2010(4):117-128. GAO H L,GU X F,YU T,et al. The research overview on visible and near-infrared channels radiometric calibration of space borne optical remote sensors[J]. Remote Sensing Information,2010(4):117-128. (in Chinese)
韩启金,傅俏燕,潘志强,等. 资源三号卫星靶标法绝对辐射定标与验证分析[J]. 红外与激光工程,2013,42(S1):167-173. HAN Q J,FU Q Y,PAN ZH Q,et al. Absolute radiometric calibration and validation analysis of ZY-3 using artificial targets[J]. Infrared and Laser Engineering,2013,42(S1):167-173. (in Chinese)
MARKHAM B L,HELDER D L. Forty-year calibrated record of earth reflected radiance from Landsat:a review. NASA Publications,Paper 70,2012. http://digitalcommons. unl. edu/nasapub/70.
李元,戎志国,郑照军,等. FY-3A扫描辐射计的可见近红外通道在轨场地定标[J]. 光学精密工程,2009,17(12):2966-2974. LI Y,RONG ZH G,ZHENG ZH J,et al. Post launch site calibration of visible and near infrared channels of FY-3A visible and infrared radiometers[J]. Opt. Precision Eng. ,2009,17(12):2966-2974. (in Chinese)
THOME K J. Absolute radiometric calibration of landsat-7 ETM+ using the reflectance-based method[J]. Remote Sensing of Environment,2001,78:27-38.
TEILLET P M,SLATER P N,DING Y,et al. Three methods for the absolute calibration of the NOAA AVHRR sensors in-flight[J]. Remote Sensing of Environment,1990,31:105-120.
JENSEN J R. Remote Sensing of the Environment:An Earth Resource Perspective[M]. Second Edition. Twin Cities:University of Minnesota,Prentice Hall,2000.
中国遥感卫星辐射校正场编. 卫星校正场地面和典型地物波谱数据集[M]. 北京:气象出版社,2007. China remote sensing radiometric calibration site compile. Spectral Data Sets for Satellite Calibration Site and Typical Earth Objects[M]. Beijing:China Meteorological Press,2007. (in Chinese)
胡秀清,张玉香,张广顺,等. 中国遥感卫星辐射校正场气溶胶光学特性观测研究[J]. 应用气象学报,2001,12(3):257-266. HU X Q,ZHANG Y X,ZHANG G SH,et al. Measurement and study of aerosol optical characteristics in China radiometric calibration sites[J]. Journal of Applied Meteorology Sciences,2001,12(3):257-266. (in Chinese)
THOME K J. Absolute radiometric calibration of landsat-7 ETM+ using the reflectance-based method[J]. Remote Sensing of Environment,2001,78:27-38.
ZHENG X B,WU H Y,ZHANG J P,et al. High-accuracy primary and transfer standards for radiometric calibration[J]. Chinese Science Bulletin,2000,45(21):2009-2013.
高海亮,顾行发,余涛,等. 基于内蒙试验场地的定标系数真实性检验方法研究与不确定性分析[J]. 中国科学:地球科学,2013,43:287-294. GAO H L,GU X F,YU T,et al. Method study and uncertainty analysis of calibration coefficients validation based on the Inner Mongolia test site[J]. Science China:Earth Sciences,2013,43:287-294. (in Chinese)
陈健,王伟国,高慧斌,等. 紫外探测器的辐射定标及标准传递[J]. 中国光学,2012(4):423-429. CHEN J,WANG W G,GAO H B,et al. Radiation calibration for UV detectors and standard transferring[J]. Chinese Optics,2012(4):423-429. (in Chinese)
傅俏燕,闵祥军,李杏朝,等. 敦煌场地CBERS-02 CCD传感器在轨绝对辐射定标研究[J]. 遥感学报,2006,10(4):433-439. FU Q Y,MIN X J,LI X CH,et al. In-flight absolute calibration of the CBERS-02 CCD sensor at the Dunhuang test site[J]. Journal of Remote Sensing,2006,10(4):433-439. (in Chinese)
0
浏览量
71
下载量
16
CSCD
关联资源
相关文章
相关作者
相关机构