浏览全部资源
扫码关注微信
中国科学院 空间应用工程与技术中心 空间应用重点实验室, 北京 100094
[ "高玉娥(1982-),女,山东人,硕士,工程师,2005年、2008年于西安电子科技大学分别获得学士、硕士学位,主要从事空间有效载荷、电子学设备的研制以及测量、控制技术的研究。E-mail:yuegao@csu.ac.cn" ]
[ "刘伟(1988-), 男, 吉林安图人, 硕士, 助理研究员, 2013年于北京理工大学获得硕士学位, 主要从事航天器动力学与控制方面的研究。E-mail:liuwei@csu.ac.cn" ]
收稿日期:2018-06-25,
录用日期:2018-8-21,
纸质出版日期:2018-12-25
移动端阅览
高玉娥, 刘伟, 吕世猛, 等. 基于位置敏感探测器的六自由度精密位姿测量系统[J]. 光学 精密工程, 2018,26(12):2930-2939.
Yu-e GAO, Wei LIU, Shi-meng LÜ, et al. Six-degree-of-freedom displacement and angle measurement system based on two-dimensional position-sensitive detector[J]. Optics and precision engineering, 2018, 26(12): 2930-2939.
高玉娥, 刘伟, 吕世猛, 等. 基于位置敏感探测器的六自由度精密位姿测量系统[J]. 光学 精密工程, 2018,26(12):2930-2939. DOI: 10.3788/OPE.20182612.2930.
Yu-e GAO, Wei LIU, Shi-meng LÜ, et al. Six-degree-of-freedom displacement and angle measurement system based on two-dimensional position-sensitive detector[J]. Optics and precision engineering, 2018, 26(12): 2930-2939. DOI: 10.3788/OPE.20182612.2930.
位置敏感探测器(Position Sensitive Detector,PSD)是一种高精度的二维位移测量传感器,利用三片二维PSD的组合实现空间六自由度相对运动的位移和角度测量。测量系统主要包括三片PSD传感器(包括PSD光敏面和发光管)、低噪声的信号调理和AD采集电路,采用三片PSD正交布局方案,通过PSD光敏面的光点位置计算相对运动的位移和角度。设计了六自由度的PSD标定测试系统,用于PSD测量系统中心偏移和发光管安装误差的标定测试。测试结果表明,PSD测量系统的测量范围优于位移±10 mm、角度±2.5°,标定后PSD测量系统的噪声误差为位移0.1 mm、角度0.02°,测量系统的绝对位移误差小于0.5 mm、角度误差小于0.14°,满足系统0.5 mm和0.5°的指标要求。此外,对PSD传感器的环境适应性进行了评估。PSD测量系统具有量程宽、精度高、线性度好的优点,成功应用于天舟1号货运飞船微重力主动隔振装置的相对运动测量中。
A Position-Sensitive Detector (PSD) was used to measure two-dimensional displacement with high precision. A combination of three two-dimensional PSDs can implement measurements of six-degree-of-freedom relative displacement and angle. The measurement system mainly comprises three PSD sensors (including PSD photosensitive surface and light-emitting tube)
low noise signal conditioning
and an Analog to Digital(AD) acquisition circuit. Three PSD orthogonal layout schemes were used to calculate the displacement and angle of relative motion through the spot position of three PSD photosensitive surfaces. A six-degree-of-freedom PSD calibration and test system was designed for the calibration of the PSD measurement system center offset and light tube installation error. The test results show that the measurement range of the PSD measurement system is better than ±10 mm and ±2.5°. The noise error of the PSD measurement system after calibration is 0.1 mm and the angle is 0.02°
while the absolute displacement error of the measuring system is less than 0.5 mm and the angle error is less than 0.14°. This proves that the system meets the requirements of 0.5 mm and 0.5°. In addition
the environmental adaptability of the PSD sensor was evaluated. It can satisfy the system requirements of noncontact
online
real-time
higher precision
and rapid speed
as well as strong anti-jamming and stabilization. The system is successfully used in the space microgravity active vibration isolation system of the Tian Zhou 1 cargo ship for relative motion measurement.
黄梅珍.位置敏感探测器的研究[D].杭州: 浙江大学, 2001. http://www.wanfangdata.com.cn/details/detail.do?_type=degree&id=Y410686
HUANG M ZH. Study on Position Sensitive Detector [D]. Hangzhou: Zhe Jiang University, 2001. (in Chinese)
林永涛. PSD综合性能检测系统的研制[D].杭州: 浙江大学, 2012. http://cdmd.cnki.com.cn/Article/CDMD-10335-1012315450.htm
LIN Y T. The Development of PSD's Comprehensive Performance Test Systems [D]. Hangzhou: Zhe Jiang University, 2012. (in Chinese)
LUO Y D, SHEN Y T, CORDERO J, et al .. Enhancing measurement accuracy of position sensitive detector (PSD) systems using the Kalman filter and distortion rectifying[J]. Sensors, 2013:1-4.
段洁, 孙向阳, 蔡敬海, 等. PSD在激光位移检测系统中的应用研究[J].红外与激光工程, 2007, 36(增):281-284.
DUAN J, SUN X Y, CAI J H, et al .. Applications research to PSD in the laser displacement detecting system[J]. Infrared and Laser Engineering, 2007, 36(suppl.):281-284. (in Chinese)
IVAN I A, ARDELEANU M, LAURENT G J. The metrology and applications of PSD (position sensitive detector) sensors for microrobotics[C]. 2012 International Symposium on Optomechatronic Technologies ( ISOT ), Paris , 2012: 1-2. https://www.researchgate.net/publication/261274362_The_metrology_and_applications_of_PSD_position_sensitive_detector_sensors_for_microrobotics
ZHANG L B, SUN F CH, SUN Z Q. Decoupling control of the two-link flexible manipulator[C]. IMACS Multiconference on Computational Engineering in Systems Application ( CESA ), 2006: 2045-2048. https://www.researchgate.net/publication/224057123_Decoupling_Control_of_the_Two-link_Flexible_Manipulator
BEZIUK G, GROBELNY A, WITKOWSKI J S, et al.. Implementation of PSD sensor for measurement of vibrations[C]. International Conference on Signals and Electronic Systems , September 14-17, 2008: 475-478. https://www.researchgate.net/publication/251864016_Implementation_of_PSD_sensor_for_measurement_of_vibrations
高经伍, 隋金雪, 赵凤华. PSD在弦振动测量中的应用[J].仪表技术与传感器, 2004(9):30-31.
GAO J W, SUI J X, ZHAO F H. Application of PSD for vibration measure[J]. Instrument Technique and Sensor, 2004(9):30-31. (in Chinese)
吴鸿, 陈冲, 李超, 等.一种基于PSD的转速测量新方法[J].电子测量与仪器学报, 2014, 28(9):1033-1039.
WU H, CHEN CH, LI CH, et al .. New method of speed measurement based on PSD[J]. Journal of Electronic Measurement and Instrumentation, 2014, 28(9):1033-1039. (in Chinese)
刘娇月, 杨聚庆, 董登峰, 等.激光跟踪仪的光电瞄准与定位系统[J].光学 精密工程, 2015, 23(6):1558-1564.
LIU J Y, YANG J Q, DONG D F, et al .. Optoelectronic aiming and orientation system of laser tracker[J]. Opt. Precision Eng., 2015, 23(6):1558-1564.(in Chinese)
SANNY OMAR. An inverse dynamics satellite attitude determination and control system with autonomous calibration[C]. 29 th Annual AIAA / USU Conference on Small Satellites , 2015: 1-12.
谷勇霞, 张玉玲, 赵杰亮, 等.柔性机械臂动力学建模理论与实验研究进展[J].中国机械工程, 2016, 27(12):1694-1703.
GU Y X, ZHANG Y L, ZHAO J L, et al .. Advances on dynamics modeling and experimental studies for flexible manipulators[J]. China Mechanical Engineering, 2016, 27(12):1694-1703.
莫长涛, 陈长征.二维PSD非线性修正共轭梯度算法[J].东北大学学报, 2003, 24(5):507-509.
MO CH T, CHEN CH ZH. Conjugate gradient optimum algorithm of non-linear correction of two-dimension PSD[J]. Journal of Northeastern University, 2003, 24(5):507-509. (in Chinese)
陈虎, 董文博, 吕世猛.精密PSD自动标定测试设备的研制与应用[C].中国空间科学学会2013年空间光学与机电技术研讨会, 2013. http://cpfd.cnki.com.cn/Article/CPFDTOTAL-ZGKK201311001071.htm
CHEN H, DONG W B, LÜ SH M. High-precision instrument for PSD calibration test[C]. SIMETC , 2013. (in Chinese)
郑军, 李文庆.基于双PSD的三维测量系统的标定方法[J].清华大学学报:自然科学版, 2018, 58(4):411-416.
ZHENG J, LI W Q. Calibration of 3-D measurement system based on a double position sensitive detectors[J]. Journal of Tsinghua University:Science and Technology, 2018, 58(4):411-416. (in Chinese)
刘春, 马颖.遗传算法和神经网络结合的PSD非线性校正[J].电子测量与仪器学报. 2015, 29(8):1157-1163.
LIU CH, MA Y. Nonlinear correction of PSD with genetic algorithm based on neural network[J]. Journal of electronic measurement and instrumentation. 2015, 29(8):1157-1163. (in Chinese)
杨鲁新, 董文博.空间载荷中利用调制光源去除PSD背景光影响的方法[J].载人航天. 2018, 24(1):55-60.
YANG L X, DONG W B. Method for mitigating background light influence on PSD by modulating light source in space payloads[J]. Manned Spaceflight, 2018, 24(1):55-60. (in Chinese)
李宗峰.空间微重力环境下主动隔振系统的三维位置测量[J].宇航学报, 2010, 31(6):1625-1629.
LI Z F. 3D position measurement of active vibration isolation system under space microgravity[J]. Journal of Astronautics, 2010, 31(6):1625-1629. (in Chinese)
LIU J, YANG H M. Three dimensional attitude measurement of the beacon based on a single PSD[J]. Optik-International Journal for Light and Electron Optics, 2017, 144(9):348-356.
董文博, 张永康, 徐振宇, 等.六自由度位姿测量方法及装置: 中国, CN107505610A[P].2017-02-22.
DONG W B, ZHANG Y K, XU ZH Y, et al .. Six-of-freedom displacement and angle measurement system method and device: Chinese Patent, CN107505610A[P].2017-02-22.(in Chinese )
0
浏览量
272
下载量
10
CSCD
关联资源
相关文章
相关作者